Sharp AR-FX7 Service Manual page 65

Digital multifunctional system option
Hide thumbs Also See for AR-FX7:
Table of Contents

Advertisement

SW70 No. 1 CED signal send
Used to set whether CED signal is sent or not. This setup is effective
only when SW43-1 (V.34 mode function) is off. This is because V.34
mode requires sending of ANSam signal.
When set to 1, CED (ANSam) signal is sent.
When set to 0, CED (ANSam) signal is not sent.
Default: 1 (CED (ANSam) signal is sent)
SW70 No. 2 CSI transmission
CSI signal includes the telephone number registered as sender's num-
ber. Used to set whether this signal is sent or not.
When set to 1, CSI signal is sent.
When set to 0, CSI signal is not sent.
Default: 1 (CSI signal is sent)
SW70 No. 3 DIS reception check in G3 send
Used to set whether DIS reception is checked or not in a send mode
other than SG3 send.
When set to 1, DIS reception is always checked twice.
When set to 0, DIS reception is checked once.
Default: 0 (1 time)
SW70 No.4, No.5 DIS process selection in reception
Used to set the process when DIS is received.
When set to 0 0, it is judged as reception of echo and the command is
sent again.
When set to 0 1, the line is disconnected as improper DIS.
When set to 1 0, when DIS judges that the receiver has poled docu-
ments, poled transmission and the other are judged as reception of an
echo and the command is sent again.
When set to 1 1, when DIS judges that the receiver has poled docu-
ments, poled transmission is made. When DIS judges that the trans-
mitter received an echo, the command is sent again. In the other case,
it is judged as improper DIS and the line is disconnected.
Default: 0 0 (Judged as reception of echo, and the command is sent
again.)
SW70 No. 6 DIS 41Bit or later enable/disable
Used to set Enable/Disable of DIS 41Bit or later
Default: 0 (Enabled)
SW70 No. 7 Time between DCS and TCF
Used to set the time between DCS and TCF.
Default: 1 (75ms)
SW70 No. 8 TCF check time
Used to set TCF check time
Default: 1 (1.0sec)
SW71 No.1–No.3 Inhibited to use.
SW71 No. 4 Telephone line menu
Used to set whether Tone/Pulse setup is displayed on the menu or not.
Default: 1 (Inhibited)
SW71 No. 5–No.8 Inhibited to use.
SW72 No.1, No.2 RCP send times
Used to set RCP send times.
Default: 0 0 (3 times)
SW72 No.3–No.6 The number of the flag detection bytes
Used to set the number of the flag detection bytes.
Setup is made in the range of 0 – 15 by binary input.
Default: 4
SW72 No. 7 EYE-Q check
Used to set whether TCF is checked or not in TCF reception.
When set to 1, check is made only with EYE-Q value. Therefore, TCF
check becomes loose.
When set to 0, check is made both with received data and EYE-Q
value.
Default: 0 (check is made both with received data and EYE-Q value. )
SW72 No. 8 Operation when error frame is received.
Used to set the operation when image data with error frame is
received.
"1": Continues process.
"0": Process is not continued. (Judged as an error.)
Default: 0 (Process is not continued. (Judged as an error.))
SW73 No. 1 Error process in RTN reception
Used to set whether RTN reception is treated as a communication
error or not.
When set to 1, it is not judged as an error when RTN is received.
When set to 0, it is judged as an error when RTN is received.
Default: 0 (it is judged as an error)
SW73 No.2, No.3 RTN send line error rate
Used to set RTN send line error rate.
Default: 1 0 (60 lines)
SW73 No.4, No.5 Flag-address timer setup (V.21-FSK)
Used to set the time between Flag-adrs during FSk signal reception in
a communication other than V.34 mode.
FSK signal reception in V.34 does not conform to this soft switch.
Default: 0 0 (6 sec)
SW73 No. 6 Reception waiting time between frames
Used to set Reception waiting time between frames.
Default: 0 (3.4sec)
SW73 No.7, No.8 Minimum flags between frames
Used to set Minimum flags between frames.
Default: 0 0 (2-flag)
SW74 No.1–No.4 FSK signal settlement time in double
wait
Used to set FSK signal settlement time in double wait.
Setup is made in the range of 200 – 950ms by binary input of N in "X
(ms) = 50 (ms) × N + 200".
N can be set in the range of 0 – 15.
Default: 400ms
SW74 No.5, No.6 Preamble send time of 300bps
Used to set the preamble send time of 300bps.
Default: 0 1 (1.0 sec)
SW74 No.7, No.8 Phase C head dummy data send time
Used to set Phase C head dummy data send time.
Default: 0 0 (0.2 sec)
SW75 No.1, No.2 Waiting time for CED send start
Used to set the waiting time for CED send start.
Default: 0 0 (2.25 sec)
SW75 No.3, No.4 CED signal send time
Used to set CED signal send time.
Default: 0 0 (3 sec)
SW75 No.5, No.6 Waiting time for ANSam send start
Used to set the waiting time for ANSam send start.
Default: 0 0 (2.25 sec)
SW75 No.7, No.8 ANSam signal send time
Used to set ANSam signal send time.
Default: 0 1 (4 sec)
AR-FX7 SOFT SWITCH 7 - 38

Advertisement

Table of Contents
loading