Download Print this page

Keysight Technologies 6811C Quick Start Manual page 52

Hide thumbs Also See for 6811C:

Advertisement

Trigger delay; no phase synchronization
Key press and d isplay
VOLT:M STEP
VOLT 120
VOLT:T 150
DELAY .0167
SYNC:SOUR IMM
INIT:IMMED
52
Resul t
When these commands are sent, the voltage amplitude changes .0167
seconds after the receipt of a trigger.
TRIG level
VOLT level
Keysight Models 6811C, 6812C, and 6813C Quick Start Guide
Trigger
Delay