5 Temperature limiter
• Electric shock hazard! High voltage inside electric panel. DO NOT touch bare
terminals and/or wires.
TC4SP unit (Fig.6) has three setting groups: 1st setting group,
2nd setting group, and SV setting group (the main indication mode).
The settings must be changed in the same order as they appear in
the list. Note that after changing In-t (temperature sensor type)
or UnI-t (temperature unit) values, parameters H-Su , L-Su , AL1 ,
AL2 , AHYS must be set again. The regulator has more parameters
than listed below; if you see a parameter not from the list, skip it and
move to the next one.
Parameters changing procedure
1. To access the 2nd group of parameters press and hold
seconds; once display reads PAr2 , release
2. To access the 1st group of parameters, press and hold
seconds; once display reads PAr1 , release
3. Press
to go through the parameters. Press
value of the parameter.
4. Press
or
5. Press
to move to the next parameter.
Group
Param
Value
2nd
LoC
oFF
2nd
In-t
YCA
2nd
L-Su
250
2nd
H-Su
400
2nd
C-nd
onoF
2nd
oUt
rLY
2nd
AL-1
An1._
2nd
AHYS
50
1st
AL1
0
1st
HYS
50
2nd
LoC
LoC2
SV
SV
350
Technical service manual 2692
to change the value.
Meaning
Unlock all settings for changing
Temperature sensor type
SV low-limit value
SV high-limit value
Control type
Control output
AL1 alarm operation mode
Alarm output hysteresis
AL1 alarm temperature
Hysteresis
All settings locked, except SV
Default temperature
DANGER
for 4
.
for 2
.
to see current
Figure 6: TC4SP panel
7