SHENZHEN RUIDA TECHNOLOGY
Read this manual before operation
The content include of electric connections and operating steps
Read the manual to operate the systems
RDC6445G/S
Building,NO.,1067
District,Shenzhen
city,Guangdong
RDC6445G/S Control System manual
Control System manual
Nanhai

Advertisement

Table of Contents
loading

Summary of Contents for Ruida Technology RDC6445S

  • Page 1 RDC6445G/S Control System manual Read this manual before operation The content include of electric connections and operating steps  Read the manual to operate the systems  RDC6445G/S Control System manual RuiDa Technology Co., Ltd Addr: floor,Technology Building,NO.,1067 Nanhai Avenue,Nanshan District,Shenzhen city,Guangdong Province,P.R.China...
  • Page 2 RuiDa, except as allowed under applicable copyright laws. We have identifiedwords that we consider as trademarks. Neither the presence or absence oftrademark identifications affects the legal status of any trademarks. SHENZHEN RUIDA TECHNOLOGY...
  • Page 3 This product has been certified by EU legislation (Restriction of Hazardous Substances) Safety certification; comply with relevant EU environmental regulations. This product has been certified by the Federal Communications Commission for safety, Comply with us electronic safety regulations. SHENZHEN RUIDA TECHNOLOGY...
  • Page 4 This sign indicates laser radiation, which is usually posted on products with laser output. Please be careful with laser and pay attention to safety when using this kind of equipment. SHENZHEN RUIDA TECHNOLOGY...
  • Page 5 If any missing parts or damaged parts are found, please contact ruida technology immediately.Do not install or debug the equipment if any obvious damage is found.
  • Page 6: Table Of Contents

    7.2 Output.............................. 28 Chapter 8 Operating Instruction of Panel....................20 8.1 Brief..............................30 8.1.1 Overview........................... 31 8.1.2 Introduction to the Keys......................31 8.2 Speed Setting........................... 33 8.3 Max/Min Power Setting........................34 8.4 Set the layer parameters........................34 8.5 Menu Function..........................35 SHENZHEN RUIDA TECHNOLOGY...
  • Page 7 8.8.4 U disk file...........................53 8.9 Password input and settings......................54 8.9.1 Password Input..........................54 8.9.2 Password Setting........................54 8.10 Prompt and alarm information...................... 55 8.11 Auto Focus............................55 Chapter 9 Manufacturer/User Parameters Explanation................56 9.1 Manufacturer parameters........................57 9.2 User parameters..........................60 SHENZHEN RUIDA TECHNOLOGY...
  • Page 8: Chapter 1 Overview

    RDC6445G/S Control System manual Section 1 Overview CONTENTS: Briefing Description of Controller Model Comparison of Controller Performance SHENZHEN RUIDA TECHNOLOGY...
  • Page 9: Briefing

    PC by USB2.0 or Ethernet, and the communication mode is automatically checked by the system. The basic functions of RDC6445G and RDC6445S are the same from the perspective of users. Only RDC6445S has on-board clock logic and uses the term encryption logic in the form of authorization code.
  • Page 10 YES (the work time Preview time accurate to time accurate to accurate to 1ms) 1ms) 1ms) Online Update Mainboard Program Online Modificatio Display Laser Feature Power/Spe Offline Modificatio Layer parameters Online Update Startup Display File dynamic/st atic preview SHENZHEN RUIDA TECHNOLOGY...
  • Page 11 PC time integrated integrated encryption hardware hardware encryption encryption included RDC6445S: Realtime clock and battery integrated authorization code encryption Communic USB2.0 10/100MHZ 10/100MHZ 10/100MHZ Ethernet Ethernet Ethernet or USB2.0, USB2.0 USB2.0 Mode communication mode automatically checked SHENZHEN RUIDA TECHNOLOGY...
  • Page 12: Chapter 2 Installation Size

    RDC6445G/S Control System manual Section 2 Installation Size CONTENTS: Installation Size of MainBoard Size of Panel SHENZHEN RUIDA TECHNOLOGY...
  • Page 13: Installation Size Of Mainboard

    The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm (the four holes are symmetrical) Figure 2.2 Size of Panel The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm. Figure SHENZHEN RUIDA TECHNOLOGY...
  • Page 14: Chapter 3 Object Pictures And Interfaces

    RDC6445G/S Control System manual Section 3 Object Pictures and Interfaces CONTENTS: Object Pictures of MainBoard Object Pictures of Panel Electric connection Lamp instruction SHENZHEN RUIDA TECHNOLOGY...
  • Page 15: Object Pictures Of Mainboard

    RDC6445G/S Control System manual 3.1 Object Pictures of MainBoard For more detailed pin description, see the Chapter 4: Description of Interface Signal for MainBoard. Figure: 3.1-1 Object Picture MainBoard SHENZHEN RUIDA TECHNOLOGY...
  • Page 16: Object Pictures Of Panel

    RDC6445G/S Control System manual 3.2 Object Pictures of Panel Figure: 3.2-1 Object Picture of Panel SHENZHEN RUIDA TECHNOLOGY...
  • Page 17: Electric Connection

    RDC6445G/S have fifteen red lamps: LED NUMBER NAME SENSE LED1 LmtX- negative limit indicator LED2 LmtX+ positive limit LED3 LmtY- negative limit LED4 LmtY+ positive limit LED5 LmtZ- negative limit LED6 LmtZ+ positive limit LED7 LmtU- negative limit SHENZHEN RUIDA TECHNOLOGY...
  • Page 18 LED8 LmtU+ positive limit LED9 Indication for water protect 1 LED10 Indication for water protect 2 LED11 Ethernet communication LED12 Link Ethernet connection LED13 error in controller hardware LED14 the normal running status LED15 +5V power supply SHENZHEN RUIDA TECHNOLOGY...
  • Page 19 RDC6445G/S Control System manual Section 4 Description of Interface Signal for MainBoard CONTENTS: Interface of Main Power Source CN0 Panel Signal-Cable Interface HMI Udisk Interface PC-USB Interface Ethernet Interface General Output Port SHENZHEN RUIDA TECHNOLOGY...
  • Page 20 RDC6445G/S Control System manual General Input Port 4-axle Spacing Input Interface CN3/CN4 X/Y/Z/U axle Motor Driver Interface AXIS_X~AXIS_U Laser Power Control Interface CN5/CN6 SHENZHEN RUIDA TECHNOLOGY...
  • Page 21: Interface Of Main Power Source Cn0

    PC-USB is a USB-BM interface. The controller may communicate with PC by this port. 4.5 Ethernet Interface Using this interface, the mainboard can communicate with PC by 10/100MHZ Ethernet. Pin to Pin Ethernet parallel line is recommended. Caution 4.6 General Output Port CN1 Definition of general output port SHENZHEN RUIDA TECHNOLOGY...
  • Page 22: General Input Port Cn2

    100ms when the pedal is stepped down once again, the second stepping-down of the pedal will be considered invalid by the mainboard. DrProc Input from protective port. If the machine needs to be protected in the special state (such as door open protection), SHENZHEN RUIDA TECHNOLOGY...
  • Page 23: 4-Axle Spacing Input Interface Cn3/Cn4

    All XYZU axle spacing inputs are compatible to 5V/12V/24V logic level inputs 。 4.9 X/Y/Z/U axle Motor Driver Interface AXIS_X~AXIS_U The interfaces of the above four motion axles are the same. The AXIS-X interface is exampled. Symbols Definitions SHENZHEN RUIDA TECHNOLOGY...
  • Page 24: Laser Power Control Interface Cn5/Cn6

    PWM end and used to control the power of the laser. The input port of water protector for the first laser power source. When the water protector 1 is enabled, the mainboard will detect SHENZHEN RUIDA TECHNOLOGY...
  • Page 25 Water protection input must be 24V logic level. L-AN1 The analog signals for Laser Power. If Glass Tube is used, this pin is recommended to control the power of the Laser. Please correctly select the laser type in the factory parameters. Prompt SHENZHEN RUIDA TECHNOLOGY...
  • Page 26: Chapter 5 Examples Of Laser Power Interface

    RDC6445G/S Control System manual Section 5 Examples of Laser Power Interface CONTENTS: Brief Examples of Glass Tube Laser Power Examples of RF-Laser SHENZHEN RUIDA TECHNOLOGY...
  • Page 27: Brief

    This control system has two independent and adjustable digital laser power control interfaces, which can be used to control glass tube laser power and RF-laser. Please correctly select the laser type in the factory parameters, or, the laser control is incorrect. SHENZHEN RUIDA TECHNOLOGY...
  • Page 28: Examples Of Glass Tube Laser Power

    RDC6445G/S Control System manual 5.2 Examples of Glass tube Laser Power SHENZHEN RUIDA TECHNOLOGY...
  • Page 29: Examples Of Rf-Laser

    RDC6445G/S Control System manual 5.3 Examples of RF-Laser SHENZHEN RUIDA TECHNOLOGY...
  • Page 30: Chapter 6 Examples Of Driver Interface For Step-Servo Motor

    RDC6445G/S Control System manual Section 6 Examples of Driver Interface for Step-servo Motor CONTENTS: Brief Examples of Motor Driver Connection SHENZHEN RUIDA TECHNOLOGY...
  • Page 31: Brief

    Figure: 6.1-1 Four Inputs, Independent Figure: 6.1-2 Three Inputs, Common-anode Input Signal of Driver Input Signal of Driver SHENZHEN RUIDA TECHNOLOGY...
  • Page 32: Examples Of Motor Driver Connection

    RDC6445G/S Control System manual 6.2 Examples of Motor Driver Connection SHENZHEN RUIDA TECHNOLOGY...
  • Page 33: Chapter7 Examples Of Io-Port Wiring

    RDC6445G/S Control System manual Section 7 Examples of IO-port Wiring CONTENTS: Input Output SHENZHEN RUIDA TECHNOLOGY...
  • Page 34: Input

    RDC6445G/S Control System manual 7.1 Input The two water protection inputs are 24V logic level; all other inputs are compatible with 5V/12V/24V logic level. Input connection shown as below Figure 7.1-1 example of input SHENZHEN RUIDA TECHNOLOGY...
  • Page 35: Output

    7.2 Output All outputs are isolated through the optocoupler, and 500mA current for each, OC gate output, each can directly drive the 6V/24V relay, led lamp, buzzer etc. Output connection shown as below Figure 7.2-1 example of output SHENZHEN RUIDA TECHNOLOGY...
  • Page 36 Section 8 Operating Instruction of Panel CONTENTS: Brief The main interface Speed Setting Max/Min Power Setting Set the layer parameters Menu Function Controller setting Funtions File Management Password input and Settings Prompt and alarm Information Auto Focus SHENZHEN RUIDA TECHNOLOGY...
  • Page 37: Brief

    Figure 8.1.1-1 Object picture of Panel Features: 5.0″TFT  854×480 resolution  64K color  RS232 standard serial communication  SHENZHEN RUIDA TECHNOLOGY...
  • Page 38: Introduction To The Keys

    Set the laser power of the current running layer, or set the power of  “Laser” Key. Special function switching.  Set the speed of the current running layer, or set the direction keys’  move speed. To stop work, or to exit to some menu.  SHENZHEN RUIDA TECHNOLOGY...
  • Page 39  Point movement and continuous motion switching.  Decimal point.  Backspace.   Digital key 0~9:Used to set parameters. 8.2 The main interface When the system is powered on, the screen will show as below: Figure SHENZHEN RUIDA TECHNOLOGY...
  • Page 40: Speed Setting

    8.2 Speed Setting Push the< Speed>key when the screen is on the main interface, it will show as below: Figure Press the number key and backspace key to set and modify the parameters. After modifying, press SHENZHEN RUIDA TECHNOLOGY...
  • Page 41: Max/Min Power Setting

    After selecting a file to preview on the main interface, If there is layer information in the layer parameter area, show as below: Figure 8.4-1 User can push <Enter> key to let the cursor move to the first layer show as below: Figure 8.4-2 SHENZHEN RUIDA TECHNOLOGY...
  • Page 42: Menu Function

    <Enter> key to save the current layer parameters, otherwise the parameters will not be saved. Press the <Esc> key interface to disappear and return to the main interface. 8.5 Menu Function Push the < Menu> key when the screen is on the main interface, it will show as below: Figure SHENZHEN RUIDA TECHNOLOGY...
  • Page 43: User Parameters

    If the user needs to modify the parameters, press the <Enter> button, and the "blue selection block" switches to the first parameter in the parameter area, as shown in the following interface: SHENZHEN RUIDA TECHNOLOGY...
  • Page 44 Figure 8.5.1-1, where the user can select another parameter category to modify or press <Esc> to return to the menu interface. Other interface operations are similar, and the interface is displayed as follows: Figure Figure 8.5.1-3 8.5.1-4 SHENZHEN RUIDA TECHNOLOGY...
  • Page 45 RDC6445G/S Control System manual Figure Figure 8.5.1-5 8.5.1-6 Figure Figure 8.5.1-7 8.5.1-8 Figure Figure 8.5.1-9 8.5.1-10 Figure 8.5.1-11 SHENZHEN RUIDA TECHNOLOGY...
  • Page 46: Vender Parameters

    In the menu interface, select "Vender parameters" entry and press the <Enter> key ,it will show as below: Figure 8.5.2-1 The interface parameters of Y, Z and U axes are the same as those of X axis parameters. Figure Figure 8.5.2-2 8.5.2-3 Figure 8.5.2-4 SHENZHEN RUIDA TECHNOLOGY...
  • Page 47: Origin Setting

    <Origin> key to set the current coordinate value to the location point 1, and finally press <Shift> key to return to the current interface operation. The operation process interface is as follows: Figure Other origins are set in the same way. 8.5.3-2 SHENZHEN RUIDA TECHNOLOGY...
  • Page 48: Backup Parameters

    Interface prompt "Backup parameter is successful". After the manufacturer regulates all parameters of the machine well (including all manufacturer parameters and user parameters), this Prompt function can be used to store the well-regulated parameters to help SHENZHEN RUIDA TECHNOLOGY...
  • Page 49: Restore Parameters

    Figure Press the <Esc> key to return to the previous menu. 8.6.1 Language Select the "Language" entry under the controller setting interface, press the <Enter> button, and then pop up the language settings interface as follows: SHENZHEN RUIDA TECHNOLOGY...
  • Page 50: Screen Origin

    X or Y directions. Press the direction key to select a item and press the <Enter> key to set up the position and press the <Esc> key return to the main interface. SHENZHEN RUIDA TECHNOLOGY...
  • Page 51: Wireless Panel

    "Write " entry and press the <Enter> key. The parameter setting takes effect. Press the <Esc> key to return to the previous menu. 8.6.4 IP Setting Select the "IP setting" entry under the controller setting interface, press the <Enter> button, and then pop up the interface as follows: SHENZHEN RUIDA TECHNOLOGY...
  • Page 52: System Info

    8.6.5 Press the <Enter> key to read motherboard information.Press the <Esc> key to return to the previous menu. 8.7 Funtions In the menu interface, select "Function" entry and press the <Enter> key ,it will show as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 53: Axis Reset

    "Resetting...". Press the <Esc> key to return to the previous menu. 8.7.2 Keyboard lock Select the "Keyboard lock" entry under the controller setting interface, press the <Enter> button, and then pop up the interface as follows: SHENZHEN RUIDA TECHNOLOGY...
  • Page 54: Manual Setting

    Please refer to section 8.9 for password input and password settings.Press the <Esc> key to return to the previous menu. 8.7.3 Manual setting Select the "Manual setting" entry under the funtions interface, press the <Enter> button, and then pop up the interface as follows: Figure 8.7.3 SHENZHEN RUIDA TECHNOLOGY...
  • Page 55: Laser Setting

    Laser key to splash the enabled lasers, and when Laser key is loosed, then the lasers will finish splashing. When the Laser mode item is “Manual”, then pushing the Laser key one time, the enabled lasers will splash a fixed time. SHENZHEN RUIDA TECHNOLOGY...
  • Page 56: Diagnose

    8.7.6 Laser power infomation Note: laser power information function is effectively configured on PC software. Select the "Laser power info" entry under the funtions interface, press the <Enter> button, and then pop up the interface as follows: Figure 8.7.6-1 SHENZHEN RUIDA TECHNOLOGY...
  • Page 57: File Management

    Press the <Esc> key to return to the previous menu. 8.8 File Management 8.8.1 Memory File Push the <Menu> key when the screen is on the main interface, it will show as below: Figure 8.8.1 SHENZHEN RUIDA TECHNOLOGY...
  • Page 58: Memory Operation

     Memery operation: the other operation of the memory files;  Read mem file: read the memory file list; 8.8.2 Memory operation Select the "Memory Operation" entry in the above interface and press the <Enter> button, then the pop-up menu appears as follows: SHENZHEN RUIDA TECHNOLOGY...
  • Page 59: Format Memery

    Select the "Format Memory" entry in the above interface and press the <Enter> button, then the pop-up menu appears as follows: Figure 8.8.3  Format speedily: To format memory speedily, and then all the files in memory will be deleted. SHENZHEN RUIDA TECHNOLOGY...
  • Page 60: U Disk File

    The file name that has only English letters and digits will not show when they are copied to the mainboard. The files copied from the mainboard to Udisk will be placed under the root directory of Udisk. SHENZHEN RUIDA TECHNOLOGY...
  • Page 61: Password Input And Settings

    If the password is correct, you can go to the next interface or perform the operation, otherwise you can display a "password error" and re-enter. Press the <Esc> key to return to the previous menu. 8.9.2 Password Setting The password settings interface is shown in the following figure: Figure 8.9.2 SHENZHEN RUIDA TECHNOLOGY...
  • Page 62: Prompt And Alarm Information

    The system generates “water protection fault”, show as below: Figure 8.10-2 At this point, the system performs related operations according to the <Enter> or <Esc> keys. 8.11 Auto Focus Push the <Focus> key when the screen is on the main interface, SHENZHEN RUIDA TECHNOLOGY...
  • Page 63: Chapter 9 Manufacturer/User Parameters Explanation

    RDC6445G/S Control System manual Section 9 Manufacturer/User Parameters Explanation CONTENTS: Manufacturer parameters User parameters SHENZHEN RUIDA TECHNOLOGY...
  • Page 64: Manufacturer Parameters

    “Reset Enable” should be prohibited.  Takeoff Speed: it means the speed of the motion axle in direct start from the idle condition. If this value is excessively large, it will make the motor lose steps, jar and even SHENZHEN RUIDA TECHNOLOGY...
  • Page 65  Laser Configuration: single laser and double lasers are available for option and set in accordance with the laser-tube quantity provided by the manufacturer.  Laser Type: glass tube, RF laser (not need pre-ignition pulse) and RF laser (needing pre-ignition pulse) available for option.  Laser Attenuation Quotiety SHENZHEN RUIDA TECHNOLOGY...
  • Page 66  Feeding Mode: it has single-way mode and two-way mode for option. If it is of single-way feeding, it is unnecessary to check the coordinates. Feeding can be conducted in the single-way mode; if it is of two-way feeding, the system will check the maximum and minimum SHENZHEN RUIDA TECHNOLOGY...
  • Page 67: User Parameters

     Idle Move Delay:If this parameter is zero, then after idle moving there is no delay, or, there is delay and the speed will decrease to turn off speed.  Turning Speed: it means the speed of turning at the acute-angle corner, which is also the highest speed in the whole cutting process. SHENZHEN RUIDA TECHNOLOGY...
  • Page 68 If the high power remains short, the lighting mode will influence the life of the laser. The system will default the selection of general mode. SHENZHEN RUIDA TECHNOLOGY...
  • Page 69 The bordering speed is the speed value set on the keyboard when the system is idle. For light output, its minimum/maximum power is the corresponding value set on the keyboard when the system is SHENZHEN RUIDA TECHNOLOGY...
  • Page 70 At this time, the controller considers the position to be the origin position of the D-axis, and then the D-axis moves to the opposite direction by a certain distance, which is the parameter. The focus value in the settings. In this mode, the material thickness parameter is invalid. Non-contact focus: SHENZHEN RUIDA TECHNOLOGY...
  • Page 71 D axis to the plane of the machine that touches the laser head) is the sum of the focal length value and the material thickness value in the parameter settings.  Backlash X: The X axes’ backlash, accurate to 1um.  Backlash Y: The Y axes’ backlash, accurate to 1um. SHENZHEN RUIDA TECHNOLOGY...
  • Page 72 RDC6445G/S Control System manual Thank you for your selection of our production! All the copyright of this manual is owned by Ruida technology. Any person or company can not copy upload and send the manual without Ruida’s permission. Content will be revised or modified. We will not send message to every users.