Page 1
User’s Manual of RDC658XG Control System Read this manual before operation The content include of electric connections and operating steps Read the manual to operate the systems RDC658XG Control System Manual RuiDa Technology Co., Ltd Addr: floor,Technology Building,NO.,1067...
Page 2
User’s Manual of RDC658XG Control System COPYRIGHT All rights reserved.You may not reproduce, transmit, store in a retrieval system or adapt thispublication, in any form or by any means, without the prior written permissionof RuiDa, except as allowed under applicable copyright laws. We have identifiedwords that we consider as trademarks.
Page 3
User’s Manual of RDC658XG Control System CERTIFICATION DECLARATION The product has been certified by the CE (Commutate European) safety certification. It has passed the corresponding conformity assessment procedure and the manufacturer's declaration of conformity, in accordance with the relevant EU directive.
Page 4
User’s Manual of RDC658XG Control System SAFETY INFORMATION When using this system, please make sure the operation is correct and the usage is safe. Some signs or text will be used to remind you to pay attention to the dangerous matters and some important information.
Page 5
If any missing parts or damaged parts are found, please contact ruida technology immediately.Do not install or debug the equipment if any obvious damage is found.
User’s Manual of RDC658XG Control System Section 1 OVERVIEW CONTENTS: BRIEFING Description of Controller Model Comparison of Controller Performance SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 1.1 Briefing RDC658XG system is a new generation system for control of laser engraving and cutting, which is developed by RD Co., Ltd. In addition to high hardware stability, high voltage or static electricity rejection, and friendly 3.5’’ TFT man-machine display. This system is provided with...
Page 10
User’s Manual of RDC658XG Control System Feature Speed Compatib Support all USB Support all USB Support all USB Support all USB ility disks with different disks with different disks with different disks with different capacities capacities capacities capacities Capacity Memory...
Page 11
User’s Manual of RDC658XG Control System Modificati Factory/User’s para on display Display 320*240 TFT 320*240 TFT 320*480 TFT 320*480 TFT display type display display display Soft Spacing Motion-axl Hard e Feature Spacing Z-axle Linkage Feeding Single/double Single/double Single/double Single/double Feature...
User’s Manual of RDC658XG Control System Section 2 Installation Size CONTENTS: Installation Size of MainBoard Size of Panel SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 2.1 Installation Size of MainBoard The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm (the four holes are symmetrical) Figure SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 2.2 Size of Panel The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm. Figure SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System Section3 Object Pictures and Interfaces CONTENTS: Object Pictures of MainBoard Object Pictures of Panel Electric connection Lamp instruction Function distribution of all eight axes SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 3.1 Object Pictures of MainBoard For more detailed pin description, see the Chapter 4: Description of Interface Signal for MainBoard. Figure: 3.1-1 Object Picture MainBoard SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 3.4 Lamp instruction RDC658XG have thirty three red lamps: LED NUMBER NAME SENSE LED1 LmtX- negative limit indicator LED2 LmtX+ positive limit LED3 LmtY- negative limit LED4 LmtY+ positive limit LED5 LmtZ- negative limit...
User’s Manual of RDC658XG Control System communication LED30 Link Ethernet connection LED31 error in controller hardware LED32 the normal running status LED33 +5V power supply 3.5 Function distribution of all eight axes The function distribution of all eight axes is as below:...
Page 21
User’s Manual of RDC658XG Control System Used to Rotating Used to Rotating Cut Used to Rotating Cut Used to control the left Axes and right moving or the fifth laser header Used to Auto-Focus Used to Auto-Focus Used to Auto-Focus...
User’s Manual of RDC658XG Control System Section 4 Description of Interface Signal for MainBoard CONTENTS: Interface of Main Power Source CN0 Panel Signal-Cable Interface HMI Udisk Interface PC-USB Interface Ethernet Interface Extended Equipment Interface CN1 SHENZHEN RUIDA TECHNOLOGY...
Page 23
User’s Manual of RDC658XG Control System Output Port CN2/CN3 Input Port CN4 8-axle Spacing Input Interface X~D axle Motor Driver Interface AXIS_X~AXIS_D Laser Power Control Interface LP1~LP6 SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 4.1 Interface of Main Power Source CN0 Symbols Definitions 24V power ground (input) +24V 24V power positive (input) This control system employs single 24 power supply. For a certain margin, it is suggested to select 24V/2A power.
User’s Manual of RDC658XG Control System 4.6 Extended Equipment Interface CN1 Symbols Definitions The TX for the first RS232 port The RX for the first RS232 port The TX for the second RS232 port The RX for the second RS232 port Power ground (output) 4.7 Output Port CN2/CN3...
User’s Manual of RDC658XG Control System All outputs are isolated through the optocoupler, and 500mA current for each, OC gate output, each can directly drive the 6V/24V relay. Prompt 4.8 Input Port CN4 Symbols Definitions Power ground (output) Stop Stop key input, used to stop the running work Shot Input for manual laser on/off.
User’s Manual of RDC658XG Control System 4.9 8-axle Spacing Input Interface X/Y axle spacing input X/Y-Lim: Symbols Definitions Power ground (output) LmtY- The spacing from axle Y- and Y to 0 coordinate LmtY+ The spacing from axle Y+ and Y to max. coordinate...
User’s Manual of RDC658XG Control System the motor driver can be broken first (otherwise the mainboard can not be detected to the spacing so as to lead to the collision of this axle), and then such a polarity can be corrected after this axle is reset completely.
Page 29
User’s Manual of RDC658XG Control System Please correctly select the laser type in the factory parameters. Prompt SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System Section 5 Examples of Laser Power Interface CONTENTS: Brief Examples of Glass tube Laser Power Examples of RF-Laser SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 5.1 Brief This control system has six independent and adjustable digital laser power control interfaces, which can be used to control glass tube laser power and RF-laser. The connection of LPn to laser power is all the same.
User’s Manual of RDC658XG Control System Section6 Examples of Driver Interface for Step-servo Motor CONTENTS: Brief Examples of Motor Driver Connection SHENZHEN RUIDA TECHNOLOGY...
5V positive output, the direction signal and the pulse signal are all OC output. RDC658XG controller must be common anode with the motor driver. The polarity of the direction signal can be changed in the factory parameters, and the valid edge of the pulse signal can also be changed.
User’s Manual of RDC658XG Control System 6.2 Examples of Motor Driver Connection The connection between the motor driver and the RDC658XG controller is given up as chapter 3.3: Electric connection. SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System Section7 Examples of Extended Equipment Interface CONTENTS: Examples of Extended Equipment Interface SHENZHEN RUIDA TECHNOLOGY...
The extended communication port, which named RTLink, that is to say CN1, included two ways RS232 ports. The first way can communicate with EPLC400 or wireless handset, which are developed by RuiDa Technology Co.,Ltd. The second way can also communicate with wireless handset or other equipments.
Page 39
User’s Manual of RDC658XG Control System Figure 7.1-2 mode2 SHENZHEN RUIDA TECHNOLOGY...
Page 40
User’s Manual of RDC658XG Control System SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System Section8 Operating Instruction of Panel CONTENTS: Introduction to the Panel and Keys Introduction to the Main Interface Z/U Key File Key Introduction to some alarm info SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 8.1 Introduction to the Panel and Keys 8.1.1 The whole panel 8.1.2 Introduction to the Keys :Reset the whole system; Reset Origin :Set the relative origin; Laser :Let the Laser to splash;...
User’s Manual of RDC658XG Control System Speed :Set the speed of the current running layer, or set the direction keys’ move speed; Max. :Set the max laser power of the current running layer, or set the power of Power “Laser”...
User’s Manual of RDC658XG Control System Figure 8.2.1 Graph Display Area: To display the whole file’s track, and display the running track. Running parameters: To display the running file’s file number, speed, max power etc. "Power1 / 2" means the first and second maximum power, "Power3 / 4" means the third and fourth maximum power, "Power5 / 6 "...
User’s Manual of RDC658XG Control System Figure 8.2.2 Push the “X+/-“ Keys to move the cursor in the numeral area, and push the “Y+/-” keys to change the value, then push the “Enter” key to save the change, push the “Esc” key to invalidate the change.
User’s Manual of RDC658XG Control System When “Z/U” key is pushed, the green block can move up and down to denote the changing item, then “Y+/-” keys and “X+/-” keys can be used to change the value. 8.2.4 Set the layer parameters After selecting a file to preview on the main interface, user can push “Enter”...
User’s Manual of RDC658XG Control System Figure 8.3 Push “Y+/-” keys to move the green block to the anticipant item, and then push the “Enter” key to display the sub menu. 8.3.1 Z move When the green block is on “Z Move” item, “X+/-” keys can be used to move the z axes.
User’s Manual of RDC658XG Control System Figure 8.3.3 When the green block is on the item, “X+/-” keys can be used to move the axes. 8.3.4 Keyboard lock function The keypad lock function to lock the operation to prevent electromagnetic interference button or human intervention.
Page 49
User’s Manual of RDC658XG Control System When the green block is on this item, push the “Enter” key to show as below: Figure 8.3.4-2 "Old password" as default password (RD8888) or the password once set, press the "Z +/-" key to move the edit box, Press the "X +/-"...
User’s Manual of RDC658XG Control System 8.3.5 Axis reset+ When the green block is on this item, push the “Enter” key to show as below: Figure 8.3.5 Push the “Y+/-“ Keys to move the cursor to one of the entry, then push “Enter” key to restart the selected axis, the screen will show some information when resetting.
User’s Manual of RDC658XG Control System push “X+-“ keys to select the anticipant value, “Continue” or “Manual”. When “Continue” item is selected, then the “Manual” item is not valid, on that time, push the direction keys to move the corresponding axes, and when the pushed key is loosed, then the corresponding axes will finish moving.
Page 52
User’s Manual of RDC658XG Control System Figure 8.3.8 Push “Z/U” key to move the green block to the anticipant item, and when the green block is on “enable” items, push “Enter” key to enable or disable the item, when enabled, the small diamonds is green, and when disabled, the small diamonds is grey.
User’s Manual of RDC658XG Control System Once the multiple- origin logic is selected and if the serial number of the next origin is 1 and four origins are enabled, when the memory Prompt file function is started or the processing file is uploaded into the PC and this file selects “Take the Original Origin as current Origin”, the...
User’s Manual of RDC658XG Control System 8.3.11 Auto Focus When the cursor stops at “Auto Focus”, press the Enter key to search for the focus(When there is z axes, and the z axes reset function is enabled, the auto focusing is valid); press the Esc key to return the prior menu.
User’s Manual of RDC658XG Control System Figure 8.3.13 Push “Z/U” key to move the changing item, then push “X+/-” keys and “Y+/-” keys to change the value, when all the IP value and the Gateway value are changed, push “Enter” key to validate the change, or “Esc”...
User’s Manual of RDC658XG Control System below: 图 8.3.14-2 When the input is validated, the color frame will be green, otherwise it’s gray automatically or push the “Enter” key to update status. 8.3.15 Screen Origin If the “Screen Origin” item is pressed, the system will show as below: Figure 8.3.15...
User’s Manual of RDC658XG Control System or Y direction. This item is only used to preview the file on the screen, and it is no meaning to the machine’s movement. Caution 8.4 File Key 8.4.1 Memory File On the main interface, if “File” key is pressed, it will show as below: Figure 8.4.1-1...
User’s Manual of RDC658XG Control System Work time: To forecast the running time of the selected file, and the time is accurate to 1ms; Clear count: To clear the running times of the selected file; Delete: To delete the selected file in the memory;...
User’s Manual of RDC658XG Control System Figure 8.4.2 Read Udisk: read the file list in the Udisk; Copy to memory: copy the target Udisk file to the memory; Delete: delete the selected Udisk file; This system supports such file formats of Udisk as FAT32 and FAT16, but it can identify them when the files are put under the root directory of Udisk.
Page 60
User’s Manual of RDC658XG Control System Please ESC Board Encrypted Contact Provider After 24 hours System be encrypted Water 1/2/3/4 error, Please ESC X/Y/XY slop over Continue press Enter Cancel press ESC No Frame Info Please ESC Tracking Frame Frame slop...
User’s Manual of RDC658XG Control System Section9 Manufacturer/User Parameters Explanation CONTENTS: Manufacturer parameters User parameters SHENZHEN RUIDA TECHNOLOGY...
User’s Manual of RDC658XG Control System 9.1 Manufacturer parameters (1)Motor parameters X~D axle parameters Direction Polarity: Modification of direction polarity can move the motor to the opposite direction. The modification purpose can move this axle to the origin on resetting.
Page 63
User’s Manual of RDC658XG Control System motor lose steps, jar and even squeak; if too small, it will cause the reduction of acceleration so as to reduce the running speed of the whole figure. For the axles with larger inertia, such as Y axle corresponding to the beam, its typical setting range is 800~3000mm/s2;...
Page 64
User’s Manual of RDC658XG Control System Laser PWM Frequency is used to set the pulse frequency of control signal used by this laser, in general, glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is used to set the limit power of this laser, that is to say, during the operation, the maximum power set by the user can’t be higher than that set here and the minimum power...
User’s Manual of RDC658XG Control System Enable parameters Door Opening Protection: If this item is enabled, then the door opening protection must be connected to the controller, or, the machine will not run. Whether to enable the blower: If using wind out port to control the blower by ...
Page 66
User’s Manual of RDC658XG Control System acceleration is changing. Speed Factor: This parameter indicates the cutting speed of the arc of various curvatures. ● Key Setting: This is a button but not a parameter, this button is used to recommend some experiential cutting parameters.
Page 67
User’s Manual of RDC658XG Control System direction will run in the same position, running one line graph, the U axes moving one time to feed, the moving length of U axes is the interval of the two lines graph on Y direction.
Page 68
User’s Manual of RDC658XG Control System invalid. (7)Rotating parameters Enable Rotating: If enable the rotating function of Y axis. If this parameter is enabled, the controller calculates the Y step length based on the circle pulse and the diameter of the work piece.
Page 69
User’s Manual of RDC658XG Control System Thank you for your selection of our production! All the copyright of this manual is owned by Ruida technology. Any person or company can not copy upload and send the manual without Ruida’s permission.
Need help?
Do you have a question about the RDC658XG and is the answer not in the manual?
Questions and answers