Control Panel

2
1
Total power drawn from all receptacles must not exceed the data decal rating.
NOTICE
1
Engine Switch – Flip the switch to the "ON(l)"
position and pull the recoil starter to start the
generator. Turn to the "OFF(O)" position to
turn off the generator.
2
4-1 Data-Minder(Multi-Meter) – Push the
SELECT button to show the Voltage, Hertz and
running hours. If the low oil indicator is lit,
check the oil level.
A - Digital display
B - AC voltage indicator
C - Frequency indicator
CO Alert™ Carbon Monoxide (CO) Shutdown
3
Indicator Light — Indicates the engine shut
down due to carbon monoxide accumulation
around the generator or a CO Alert system
fault occurred.
4
120/240V, 30A Twist Lock – (NEMA L14-30R)
Maximum 27.9 Amp current maybe drawn
from this 120/240 Volt receptacle.
120V, 30A Twist Lock (NEMA L5-30R)
5
Maximum 30 Amp current may be drawn
from this 120 Volt receptacle.
English
3
D - Hour indicator
E - Low oil indicator
F - Select button
5
4
120V, 20A Duplex GFCI (Ground Fault
6
Circuit Interrupter) – (NEMA 5-20R)
This receptacle is rated so that a total of 20
Amp may be drawn regardless of whether
both halves or just one receptacle is used.
Ground Fault Circuit Interrupter conforms to
UL 943 and NEC requirements. This device
protects you against hazardous electrical shock
that may be caused if your body becomes a
path through which electricity travels to reach
ground. This could happen when you touch an
appliance or cord that is " live " through faulty
mechanism, damp or worn insulation, etc.
Ground Terminal – Consult an electrician
7
for local grounding regulations.
8
Outlet Cover - Protect the receptacles from
9
dust and debris.