Page 1
OWNER’S MANUAL PORTABLE GENERATOR MODEL NUMBER P01001 Rev Level:02 Read all safety precautions and instructions carefully IMPORTANT: before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
INTRODUCTION Thank you for purchasing a FIRMAN generator. Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual and the tags and decals affixed to the unit are therefore not all-inclusive.
Page 5
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
Page 6
WHEN OPERATING EQUIPMENT WARNING • • DO NOT tip engine or equipment at angle which causes fuel to spill. • DO NOT stop engine by moving choke • control to “Start” position. WHEN TRANSPORTING, MOVING • OR REPAIRING EQUIPMENT • NEVER start or stop engine with electrical Transport/move/repair with fuel tank devices plugged in and turned on.
Page 7
• When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
Install the Handle 1. Secure the handle to the fuel tank using the two handle bolts B(M6X30) and rubber washers C. 2. Use the supplied screwdriver to fasten securely. DO NOT over tighten the bolts. 3. Place the plug D into the handle.
4- Fuel Cap 5- Choke Lever 6- Fuel Valve 7- Air Filter 8- 80cc FIRMAN OHV Engine 9- Recoil Starter *We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on this page.
Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Switch – Flip the switch to the “ON”(l) 12V DC outlet – 8.3 Amp of DC current position and pull the recoil starter to start may be drawn from the receptacle.
SPECIFICATIONS Model P01001 Starting Watts 1300 1050 Running Watts Rated AC Voltage 120V Rated Fequency 60Hz Phase Single Phase Voltage regulator Capacitor Power Factor Alternator Type Brushless Engine FIRMAN Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Displacement 80 cc...
4.Using oil funnel, slowly pour contents of Add Engine Oil provided oil bottle into oil fill opening to the "H" mark on dipstick. Be careful do not CAUTION overfill. Overfilling with oil could cause the engine to not start or hard starting. NOTE: Degrees Celsiusº(Outside) 5.Replace oil fill cap/dipstick and fully tighten.
Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • Use regular UNLEADED gasoline with the generator engine with a minimum 87 octane / 87 AKI (91 RON). For high altitude use, see "Operation at High Altitude". •...
THE GENERATOR (STATOR WINDING) AND THE Installation instructions are also available in the FRAME. Technical Bulletin area of the FIRMAN internet site. The part number and recommended minimum Connecting to a Building's Electrical System altitude for the application of the high altitude carburetor main jet is listed in the table below.
OPERATION • Generator Location WARNING Make sure you review each warning in order to • prevent fire hazard. Keep area clear of inflammables or other hazardous materials. Select a site that is dry, well ventilated and protected from the weather. •...
7. Pull the starter cord slowly until resistance is Starting the Generator felt and then pull rapidly. 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 8.
Connecting Electrical Loads This unit has been pretested and adjusted to handle its full capacity. Before starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for 12V DC Outlet (Battery Charger) correct output.
Let the generator run at no-load for two 2. Plug the battery charging cable into the DC minutes to stabilize internal temperatures receptacle of the generator. of the engine and generator. 3. Connect the red (+) battery charger lead to the red (+) battery terminal.
If oil level is between LOW and HIGH mark on dipstick: 1.DO NOT try to restart the engine. 2.Contact an Authorized FIRMAN Service Dealer. 3.DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1.Add oil to bring level to HIGH mark.
• Use fresh and high quality lubricating oil to the ENGINE MAINTENANCE specified quantity. If contaminated or deteriorated oil is used or To prevent accidental starting, remove and the quantity of the engine oil is not sufficient, ground spark plug wire before performing any the engine damage will result and its life will be service.
Spark Plug Maintenance CLEANING FUEL STRAINER Changing the spark plug will help your engine Clean the screen with gasoline every 50 hours. to start easier and run better. (a) Remove the spark plug cap. (b) Remove spark plug using provided wrench. SCREEN BODY A- Spark plug...
• DO NOT touch hot parts and AVOID hot exhaust CAUTION gases. • Failure to clean the spark arrester will result in Allow equipment to cool before touching. degraded engine performance. • Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
DANGER SERVICE AND STORAGE Drain fuel into approved container outdoors, Infrequent Service away from open flame. Be sure engine is cool. If the unit is used infrequently, difficult starting Do not smoke. may result. To eliminate hard starting, follow 4-FUEL STARVATION: Start and run the generator these instructions: until it stops from lack of fuel.
TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
P01001 Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description 312713518 Bolt M6x10 310715022 Bolt M4x16 310755000 Voltmeter 312713510 Nut M4 310715008 Nut M3 310715023 Flat Washer Ø4 310715009 Flat Washer Ø3 312713505 Lock Washer Ø6 310715010 Screw St3.5x12.5...
Page 30
152F 80cc Engine Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description 312723500 Starter 312723552 Oil Channel Cover 312723501 Screw M6×10 (black) 312723553 Valve Spring 312723502 Flywheel Nut 312723554 Valve Retainer 312723503 Screw M6×12 312723555 Rocker Arm Seat 312723504 Fan Cas 312723556...