Firman P05702 Owner's Manual
Hide thumbs Also See for P05702:

Advertisement

Quick Links

OWNER'S MANUAL
PORTABLE GENERATOR
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-844-347-6261
FOR QUESTIONS OR SERVICE
INFORMATION
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
MODEL NUMBER
P05702
Serial Number:
Purchase Date:
P/N:357745451 Rev:00
Rev Level:00

Advertisement

Table of Contents
loading

Summary of Contents for Firman P05702

  • Page 1 OWNER’S MANUAL PORTABLE GENERATOR MODEL NUMBER P05702 Rev Level:00 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
  • Page 2: Table Of Contents

    Table of Contents Introduction ......1 Maintenance And Storage....23 Safety Precautions .
  • Page 3: Introduction

    Save these original instructions for future reference. This manual covers operation and maintenance of the FIRMAN generators. All information in this publication is based on the latest production information available at the time of approval for printing.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS WARNING WARNING • WARNING POISONOUS GAS HAZARD. • • • • English Page 02 Customer Service: 1-844-FIRMAN1...
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
  • Page 6 WHEN OPERATING EQUIPMENT WARNING • • DO NOT tip engine or equipment at angle which causes fuel to spill. • DO NOT stop engine by moving choke • control to “Start” position. WHEN TRANSPORTING, MOVING • OR REPAIRING EQUIPMENT • NEVER start or stop engine with electrical Transport/move/repair with fuel tank devices plugged in and turned on.
  • Page 7 • When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
  • Page 8: Unpacking The Generator

    NOTE: 1. Axle pin ....... . .2 Improper treatment of generator could damage 2.
  • Page 9: Assembly

    ASSEMBLY Install the Handle The generator requires some assembly prior to 1. Place the handle K over the mounting channel usage. If problems arise when assembling the on the frame. generator, call 1-844-347-6261. 2. Secure the handle to the frame using the two Install the Wheel Kit handle flange bolts H(M8x50).
  • Page 10: Battery Cable Connection

    Battery Cable Connection You will need to use 8mm box wrenches to connect the battery cables to battery. NOTE: The generator comes equiped with the positive red cable(red cable) already attached. 1. Verify the positive (+) battery cable (red boot) is securely tightened to the positive (+) battery post.
  • Page 11: Controls And Features

    5- Fuel Valve 13- Handle 6- Air Filter 14- Battery 7- 389cc FIRMAN OHV Engine 8- Recoil Starter *We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on this page. English...
  • Page 12: Control Panel

    Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Start Switch – Used to start engine 120V, 30A Twist-Lock (NEMA L5-30R) from the starter motor(Electric start model 30 Amp current may be drawn from this 120 Volt receptacle.
  • Page 13: Remote Start

    120VAC, 20AMP GFCI RECEPTACLE 5. To restore the flow of electricity, press the “RESET” button on the front of the receptacle. This unit is equipped with a ground fault circuit If the GFCI does not perform in this manner, do interrupter (GFCI).
  • Page 14: Remote Control Programming

    Remote Control Programming 4. Push and release the ''STOP'' button on the remote control. The indicator light will flash Before the generator can be started , an initial once to erase the remote program. start-up procedure must be performed so the generator and the remote control recognize STOP each other.
  • Page 15: Specifications

    SPECIFICATIONS Model P05702 Starting Watts 7125 5700 Running Watts Rated AC Voltage 120/240V Rated Fequency 60Hz Phase Single Voltage Regulator Power Factor Alternator Type Brushed Engine FIRMAN Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Displacement 389cc Low Oil Shutdown...
  • Page 16: Add Engine Oil

    4.Using oil funnel, slowly pour contents of ADD ENGINE OIL provided oil bottle into oil fill opening to the "H" mark on dipstick. Be careful do not CAUTION overfill. Overfilling with oil could cause the engine to not start or hard starting. NOTE: Degrees Celsiusº(Outside) 5.Replace oil fill cap/dipstick and fully tighten.
  • Page 17: Add Fuel

    To alleviate high fuel expansion. altitude issues other than the natural 3.Install fuel cap and let any spilled fuel power loss, FIRMAN can provide a high evaporate before starting engine or wipe up altitude carburetor main jet. The alternative any spilled gasoline.
  • Page 18: Grounding

    Connecting to a Building's Electrical System obtained by contacting Customer Support. Installation instructions are also available in the Technical Bulletin area of the FIRMAN internet site. The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below.
  • Page 19: Operation

    5. OPERATION • Generator Location WARNING Make sure you review each warning in order to • prevent fire hazard. Keep area clear of inflammables or other hazardous materials. Select a site that is dry, well ventilated and protected from the weather. •...
  • Page 20: Starting The Generator (Recoil Start)

    Starting the Generator (Recoil Start) 7. Move the choke lever to the “START” position. 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 8.
  • Page 21: Starting The Generator (Electric Start)

    4. Turn the fuel valve to the “ON” (l)position. Starting the Generator (Electric Start) Electric Start and Remote Start Operations 5. Flip the engine switch to the "RUN"(l) position. WARNING 6. Flip the battery switch to the "ON"(l) position. WARNING 7.
  • Page 22: Starting The Generator (Remote Start)

    9. Do not over-choke. As soon as engine starts and warms up, move the choke lever to the “RUN” position. 4. Turn the fuel valve to the “ON” (l)position. 10. Allow generator to run at no load for few minutes upon each initial start-up to permit engine and generator to stablize.
  • Page 23: Connecting Electrical Loads

    If the engine fails to start within 3 to 5 seconds, the engine will attempt to start five additional times. If the generator failed to start, the remote start indicator light will flash. If the generator fails to start after a total of six attempts, the start button on the remote control must be pushed again to begin another cycle of six start attempts.
  • Page 24: Low Oil Shutdown

    1.DO NOT try to restart the engine. 4. Flip the battery switch on "OFF"(O) position. 2.Contact an Authorized FIRMAN Service Dealer. 3.DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1.Add oil to bring level to HIGH mark.
  • Page 25: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Every Daily(Before Initial Every 100 hours ITEM NOTES operation) 25 hours 50 hours (or annual) Check condition. Adjust gap √ Spark Plug and clean. Replace if necessary. √ Check oil level. Engine Oil √ √ Replace.
  • Page 26: Engine Maintenance

    • Use fresh and high quality lubricating oil to the ENGINE MAINTENANCE specified quantity. If contaminated or deteriorated oil is used or To prevent accidental starting, remove and the quantity of the engine oil is not sufficient, ground spark plug wire before performing any the engine damage will result and its life will be service.
  • Page 27: Spark Plug Maintenance

    Spark Plug Maintenance Cleaning Fuel Strainer Changing the spark plug will help your engine Dirt and water in the fuel are removed by the fuel to start easier and run better. strainer. (a) Remove the spark plug cap. (b) Remove spark plug using provided wrench. (a) Remove the strainer cup and throw away water and dirt.
  • Page 28: Generator Maintenance

    • DO NOT touch hot parts and AVOID hot exhaust CAUTION gases. • Failure to clean the spark arrester will result in Allow equipment to cool before touching. degraded engine performance. • Keep at least 5 feet (1.5 m) of clearance on all GENERATOR MAINTENANCE sides of generator including overhead.
  • Page 29: Service And Storage

    WARNING Long Term Storage When the generator set is not being operated or is being stored more than one month, follow these instructions: 1. Replenish engine oil to upper level. 2. Run the generator, then close the fuel shut-off To avoid electric shock: valve and allow the unit to run until the engine ALWAYS connect the positive (+) battery cable stops.
  • Page 30: Trouble Shooting

    TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
  • Page 31: Parts Diagram And Parts List

    PARTS DIAGRAM AND PART LIST P05702 PARTS DIAGRAM Page 29 English Customer Service: 1-844-FIRMAN1...
  • Page 32: Engine Parts Diagram

    389cc ENGINE PARTS DIAGRAM Page 30 English Customer Service: 1-844-FIRMAN1...
  • Page 33: Parts List

    P05702 PARTS LIST Description Qty. Description Qty. NO. Part Number NO. Part Number Fuel Valve FIRMAN 389cc Engine 357713560 336713551 Nut M10 357713501 Rubber Cap B 357713531 Isolator B 336713528 Flange Bolt M6×8 357713532 Isolator A 357713502 Generator Wind Shield...
  • Page 34 FIRMAN 389cc Engine Parts List Qty. Qty. NO. Part Number NO. Part Number Description Description Crankcase Subassembly. Spring 357723500 336723601 Bolt, Drain Plug Step Moter Holder 357723501 357723553 Washer,Drain Bolt Step Moter 357723502 336723603 Sensor, Engine Oil Bolt M4×8 357723503 336723604 Flg.
  • Page 35: Service Information

    1. Model No. ,Rev. Level and Serial No. and all of Purchase specifications shown on the Model No./Serial Contact the FIRMAN Service Center and FIRMAN No. plate. will troubleshoot any issue via phone or e-mail. 2. Parts number or numbers as shown in the If the problem is not corrected by this method, Parts List section.
  • Page 36 Kennesaw GA, 30144 Normal maintenance is not covered by this www.firmangenerators.com warranty. We are FIRMAN POWER - And we are here for you. Other Exclusions Customer Service Desk - 1-844-347-6261(844-FIRMAN1) This warranty excludes: 6am PST(9am EST) until 8pm EST(5pm PST) –...
  • Page 37 If any such part fails during the period of warranty coverage, the part will be repaired or replaced by FIRMAN at no charge to the owner. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.
  • Page 38 (a) Consequential damages such as loss of time, inconvenience, loss of use of the engine or equipment, etc. (b) Diagnosis and inspection fees that do not result in eligible warranty service being performed. FIRMAN POWER EQUIPMENT INC. Page 36 English...
  • Page 39 Firman Power Equipment Inc. 3939 Royal Drive NW, Suite 222 Kennesaw GA, 30144 www.firmangenerators.com P/N:357745451 Rev 0 0...

Table of Contents