Combination In Use Of Remote, Unit Operating Panel, And Pc - Pioneer PDM-4001 Technical Manual

Table of Contents

Advertisement

1) Normal Operating Mode
Intended for video playback, this mode enables the following basic operations:
• Switching to STANDBY status (POWER OFF)
• Input switching
• Key Lock/Unlock switching (this must be done using a button found only on the main unit.)
• Switching to Menu or RS-232C adjustment mode
Additionally, Normal operating mode also enables some of the RS-232C controls (as discussed in "5.4.3 RS-
232C Commands").
2) Menu Mode
Use this mode to set picture quality, image position, and other characteristics.
Refer to "5.3 Menu Mode" for further details.
The mode allows you to change adjustment data within certain limits, based on values adjusted in Integrator
or RS-232C adjustment modes (discussed later).
For more information, refer to "5.2 Menu Mode."
3) Integrator Mode
This mode provides adjustment functions for the integrator.
White balance adjustment and various other setting items are available in addition to those in Menu mode.
Refer to "5.3 Integrator Mode" for further details.
4) RS-232C Adjustment Mode
This mode enables various adjustments and settings using a PC.
Some adjustment items are available only in this mode.
Refer to "5.4 RS-232C Adjustment Mode" for further details.
Combination use of remote, Unit operation panel, and PC.

5.1.2 Combination in use of remote, unit operating panel, and PC

• The remote, and the operating panel of the main unit may be used together.
Example: You can enter Menu mode through the operating panel of the main unit, then make adjustments
using the remote.
• Depending on which has transmitted the more recent command, either the remote or the operating panel(of the
main unit), or RS-232C may originate the command currently in effect.
Example:
Press the MENU button on the remote
(or on the operating panel of the main
unit)
Now, issue an <AJY> command from
a PC.
Operation
Before making adjustments
= Enters Menu mode.
At this time, the only available RS-232C commands are:
• <AJY>
• <POF>
= Menu mode is disabled and RS-232C adjustment mode
is activated. At this time, only the following options are
available from the remote(or the operating panel of the
main unit):
• Power switch
• MENU button
• KEY LOCK/UNLOCK button
Action
133

Advertisement

Table of Contents
loading