J. Detailed Component Operating
Instructions - IntelliFire Touch
IFT-ECM Detailed Operating Instruction
This model is shipped from the factory equipped with the
IFT-RC400 remote.
1. The Electronic Control Module (IFT-ECM) has a
three-position ON/OFF/REMOTE selector switch
that must be set for proper operation. See Figure
3.7. When changing switch positions, it is important
to pause in each position for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands
from the IFT-RC150 or IFT-RC400 remote controls.
The unit should be in the OFF position during
service, fuel conversion. When switched to the OFF
position while the appliance is operating, the system
will shut down.
ON Position:
The appliance will ignite and run continuously at
the HI flame setting. No adjustment in flame height
is possible.
Remote Position:
The remote position allows operation of the
appliance from the IFT-RC400 or IFT-RC150
remote controls. The IFT-ECM switch must be in
this position to pair the IFT-ECM with the IFT-ACM
(if installed), and/or IFT-RC400 and IFT-RC150
remote controls. See the IFT-RC400 or IFT-
RC150 installation manual for detailed instructions
on pairing the IFT-ECM with the remote controls.
After successfully pairing a IFT-RC400, all installed
accessories can be controlled by the IFT-RC400
(see IFT-RC400 user manual). The RC150 allows
the user to turn ON/OFF the flame in the appliance
and activate the Cold Climate mode if desired. The
IFT-ECM has a safety feature that will automatically
shut down the fireplace after 9 hours of continuous
operation without receiving a command from the
IFT-RC400 or IFT-RC150.
The IFT-ECM has a safety feature that will
automatically shut down the fireplace after 9
hours of continuous operation in the ON position,
except when operated in active thermostat mode.
2. If multiple control options are installed, the IFT-ECM
will respond to the last command from the IFT-RC400
or IFT-RC150. The Pilot button on the IFT-ECM
activates the Cold Climate function of the fireplace.