Manually Rebuilding Array - HIKVISION DS-7608NI-K2/8P/4G User Manual

Hide thumbs Also See for DS-7608NI-K2/8P/4G:
Table of Contents

Advertisement

If there is no hot spare disk after rebuilding, it is recommended to install a HDD into the device and
set is as a hot spare disk to ensure the high security and reliability of the array.

13.2.3 Manually Rebuilding Array

Purpose:
If the hot spare disk has not been configured, you can rebuild the array manually to restore the
array when the virtual disk is in Degraded status.
Step 1 Enter the Array Settings interface. The disk 3 is lost.
Menu > HDD > RAID > Array
Step 2 Click Array tab to back to the Array Settings interface and click
rebuild.
At least one available physical disk should exist for rebuilding the array.
Network Video Recorder User Manual
Figure 1. 2 Array Settings Interface
Figure 13-11 Array Settings Interface
223
to configure the array