Toshiba RAV-RM1601BTP Series Service Manual page 67

Table of Contents

Advertisement

DN
Item
60
Timer set
(Wired remote controller)
8b
Correction of high heat feeling
42
Self clean time
C2
Power saving
(Current demand × % to outdoor unit)
CC
Forced stop setting for self clean
CD
Self clean stop function when [START/
STOP] operation was prohibited
D0
Existence of Power save operation
D1
Existence of 8°C heating operation
function
D3
Revolution count of self clean
D4
Display/ No display of [SELF CLEANING]
during self clean operation
Fan speed tab
D6
Description
0000 : Available (Operable)
0001 : Unavailable (Operation prohibited)
0000 : None
0000: None
0001: 0.5h to 0.012: 6.0h
The case that compressor-ON time is 10 to 60 minutes is
set up. When ON time is over 60 minutes, the operating
time becomes two times of it.
0050: 50%
to
0100: 100%
0000: None
0001: Set
When stopping the air conditioner (including "Fire alarm"
of the control system, etc.) while [START/STOP] operation
is prohibited (Central 1, 2) from the central controller side,
0000: Valid (No self cleaning)
0001: Invalid (Self cleaning)
0000: Invalid (Unavailable)
0001: Valid (Available)
0000: Invalid (Unavailable)}
0001: Valid (Available)
0000: Invalid (Self cleaning is not performed.)
0011: Valid (Self cleaning is performed at 310 rpm.)
0000: Displayed, 0001: Not displayed
0000: 3 tab
0001: 5 tab
- 67 -
FILE NO. SVM-18039
0001 : Correction
At shipment
0000 : Available
0000 : None
0000: None
0075: 75%
0000: None
0000: Valid
0001: Valid (Available)
0000: Invalid
(Unavailable)
0011: 310 rpm
0000: Displayed
0001: 5 tab