Table of Contents

Advertisement

Quick Links

Owner's Manual
GENERATOR
EB2200i
See page 79 for Initial Use Instructions.
2019 Honda Motor Co., Ltd. -All Rights Reserved
C

Advertisement

Table of Contents
loading

Summary of Contents for Honda EB2200ITAN

  • Page 1 Owner’s Manual GENERATOR EB2200i See page 79 for Initial Use Instructions. 2019 Honda Motor Co., Ltd. -All Rights Reserved...
  • Page 2 The information and specifications included in this publication were in effect at the time of approval for printing. Honda Motor Co., Ltd. reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatsoever.
  • Page 3 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely.
  • Page 4 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual.
  • Page 5: Table Of Contents

    CONTENTS GENERATOR SAFETY ................6 IMPORTANT SAFETY INFORMATION ..........6 Operator Responsibility..............6 Carbon Monoxide Hazards............... 6 Electric Shock Hazards ..............7 Fire and Burn Hazards ..............7 Refuel With Care ................7 SAFETY LABEL LOCATIONS ..............8 CONTROLS & FEATURES ..............10 COMPONENT & CONTROL LOCATIONS ..........10 CONTROLS ..................12 Engine Switch .................
  • Page 6 CONTENTS OPERATION ....................22 SAFE OPERATING PRECAUTIONS ............22 STARTING THE ENGINE ..............23 STOPPING THE ENGINE ..............26 GFCI OPERATION CHECK ..............27 AC OPERATION ...................30 AC Applications................32 ® ECO THROTTLE SYSTEM ..............33 STANDBY POWER ................34 Connections to a Building’s Electrical System ......34 System Ground ................
  • Page 7 CONSUMER INFORMATION ..............67 Dealer Locator Information ..............67 Honda Publications ................67 Customer Service Information ............68 Distributor’s Limited Warranty ............69 Honda Parts, Accessories, and Apparel ..........72 Emission Control System Warranty ..........74 INITIAL USE INSTRUCTIONS ..............79 ENGINE OIL ..................79 FUEL .....................80 BEFORE OPERATION ................82 REGISTRATION ...................82...
  • Page 8: Generator Safety

    GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all of the instructions in this manual and on the generator.
  • Page 9: Electric Shock Hazards

    GENERATOR SAFETY Electric Shock Hazards • The generator produces enough electric power to cause a serious shock or electrocution if misused. • Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.
  • Page 10: Safety Label Locations

    GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
  • Page 11 GENERATOR SAFETY...
  • Page 12: Controls & Features

    CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls. AIR CLEANER CHOKE LEVER FUEL FILLER CAP VENT LEVER FUEL FILLER CAP MAINTENANCE COVER STARTER GRIP ENGINE SWITCH SPARK PLUG SPARK PLUG MAINTENANCE COVER MUFFLER...
  • Page 13 CONTROLS & FEATURES GFCI RECEPTACLES ECO THROTTLE SWITCH OIL ALERT INDICATOR OVERLOAD INDICATOR OUTPUT INDICATOR GROUND TERMINAL...
  • Page 14: Controls

    CONTROLS & FEATURES CONTROLS Engine Switch ENGINE SWITCH The engine switch controls the ignition system and the fuel valve. OFF – Stops the engine and closes the fuel valve. FUEL OFF – Keeps the ignition FUEL OFF system ON, and closes only the fuel valve (see page 26).
  • Page 15: Fuel Filler Cap Vent Lever

    CONTROLS & FEATURES Fuel Filler Cap Vent Lever The fuel filler cap is provided with a fuel filler cap vent lever to seal the fuel tank. The fuel filler cap vent lever must be in the ON position for the engine to run.
  • Page 16: Eco Throttle ® Switch

    CONTROLS & FEATURES ® Eco Throttle Switch ® The Eco Throttle system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load.
  • Page 17: Ground Fault Circuit Interrupter (Gfci) Receptacle

    CONTROLS & FEATURES Ground Fault Circuit Interrupter (GFCI) Receptacle The 120 V 20 A duplex receptacle is protected by a Ground Fault Circuit Interrupter (GFCI) for protection against the shock hazard of ground fault currents. An example of ground fault current is the current that would flow through a person who is using an appliance with faulty insulation and, at the same time, is in contact with an electrical ground such as a plumbing fixture, wet floor, or earth.
  • Page 18: Features

    CONTROLS & FEATURES FEATURES Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
  • Page 19: Output Indicator

    CONTROLS & FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. In addition, the output indicator has a simplified hour meter function. When you start the engine, the indicator blinks according to the generator’s cumulative operating hours as follows: •...
  • Page 20: Overload Alarm (Indicator)

    CONTROLS & FEATURES Overload Alarm (Indicator) If the generator is overloaded (in excess of 2.2 kVA), or if there is a short circuit in a connected appliance, the overload indicator (red) will come ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF .
  • Page 21: Led Light Patterns

    CONTROLS & FEATURES LED Light Patterns OIL ALERT INDICATOR OVERLOAD INDICATOR OUTPUT INDICATOR Status Possible cause Output Indicator Overload Indicator Oil Alert Indicator Normal Operating normally Malfunction Inverter unit failure Abnormal Output overcurrent Inverter unit overheat Warning Engine oil low : ON : OFF : Blinking...
  • Page 22: Before Operation

    BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it.
  • Page 23: Check The Engine

    BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level and firm surface and the engine switch is in the OFF position.
  • Page 24: Operation

    OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page 6) and BEFORE OPERATION (see page 20). For your safety, do not operate the generator in an enclosed area such as a garage.
  • Page 25: Starting The Engine

    OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. • Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator.
  • Page 26 OPERATION 3. Make sure the Eco Throttle ECO THROTTLE SWITCH switch is in the OFF position, or more time will be required for warm-up. 4. To start a cold engine, move CHOKE LEVER the choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position.
  • Page 27 OPERATION 6. Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. Direction to pull Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter.
  • Page 28: Stopping The Engine

    OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position securely. Under normal conditions, use the following procedure. 1. Turn off or disconnect all appliances that are connected to the generator.
  • Page 29: Gfci Operation Check

    Always perform the GFCI system inspection before using the generator. If the GFCI system fails the test, the generator must be repaired by an authorized Honda servicing dealer before use. GFCI RECEPTACLE (120 V 20 A DUPLEX RECEPTACLE)
  • Page 30 • If the green indicator light does not come on, press the RESET button. • If the red indicator starts to blink continuously, contact an authorized Honda generator dealer. 3. Press the TEST button: • The RESET button will pop out and the green indicator will go off.
  • Page 31 4. Press the RESET button: • The green indicator will light continuously. • If the red indicator starts to blink continuously, contact an authorized Honda generator dealer. RESET BUTTON INDICATOR When the RESET button pops out or the green indicator does not lit during operation: •...
  • Page 32: Ac Operation

    OPERATION AC OPERATION Before connecting an appliance to the generator, make sure that it is in good working order and that its electrical rating does not exceed that of the generator. Most motorized appliances require more than their electrical rating for startup.
  • Page 33 OPERATION 2. Plug the appliance into the receptacle. 3. Turn on the appliance. If the generator is overloaded (see page 32), or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
  • Page 34: Ac Applications

    OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 35: Eco Throttle ® System

    OPERATION ® ECO THROTTLE SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the ®...
  • Page 36: Standby Power

    Do not connect an EB2200i generator to a home or building's electrical system. The Honda EB2200i generator is designed for construction job site use and cannot be connected to a building's electrical system. This generator has the neutral bonded to ground to comply with OSHA job site temporary power regulation.
  • Page 37: Servicing Your Generator

    Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it. To ensure the best quality and reliability, use only new, Honda Genuine parts or their equivalents for repair and replacement.
  • Page 38: Maintenance Safety

    SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Improper maintenance can cause an unsafe condition.
  • Page 39: Maintenance Schedule

    (1) Service more frequently when used in dusty areas. (2) These items should be serviced by your servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to the Honda shop manual for service procedures. See ‘‘Honda Publications’’ on page 67 for ordering information.
  • Page 40: Refueling

    SERVICING YOUR GENERATOR REFUELING With the engine stopped, remove the fuel filler cap and check the fuel level. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel.
  • Page 41: Fuel Recommendations

    SERVICING YOUR GENERATOR FUEL FILLER CAP UPPER LEVEL MARK (RED) TETHER FUEL FILTER After refueling, tighten the fuel filler cap until it clicks. FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use gasoline that is stale, contaminated, or mixed with oil.
  • Page 42: Engine Oil Level Check

    SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. 1. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 2. Remove the oil filler cap and wipe the dipstick clean. 3.
  • Page 43: Engine Oil Change

    SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. 1. Turn the engine switch and fuel filler cap vent lever to the OFF position (see page 26) to reduce the possibility of fuel leakage. 2.
  • Page 44: Engine Oil Recommendations

    AMBIENT TEMPERATURE The SAE oil viscosity and service category are in the API label on the oil container. Honda recommends that you use API service category SJ or later (or equivalent) oil.
  • Page 45: Air Cleaner Service

    SERVICING YOUR GENERATOR AIR CLEANER SERVICE MAINTENANCE COVER SCREW 1. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE 2. Loosen the air cleaner cover COVER AIR CLEANER CASE screw, and remove the air MAIN FILTER cleaner cover. 3.
  • Page 46 SERVICING YOUR GENERATOR 5. Reinstall the air filters. AIR CLEANER COVER 6. Make sure that the rubber seal is set in the groove of the air cleaner cover. 7. Reinstall the air cleaner cover, and tighten the air cleaner cover screw. RUBBER SEAL 8.
  • Page 47: Main And Outer Filters Cleaning

    SERVICING YOUR GENERATOR MAIN AND OUTER FILTERS CLEANING Dirty main and outer filters will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the main and outer filters more frequently than specified in the MAINTENANCE SCHEDULE (see page 37).
  • Page 48: Spark Plug Service

    SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Spark plug: CR5HSB (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage.
  • Page 49 SERVICING YOUR GENERATOR 5. Inspect the spark plug. Replace it SIDE ELECTRODE if the electrode is worn or if the SEALING WASHER insulator is cracked, chipped, or 0.024–0.028 in fouled. (0.6–0.7 mm) 6. Measure the spark plug electrode gap with a wire-type feeler gauge.
  • Page 50: Spark Arrester Service

    SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1.
  • Page 51 SERVICING YOUR GENERATOR 3. Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged. 4.
  • Page 52: Storage

    STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.
  • Page 53 Drain the fuel tank and carburetor (see page 52). Change the engine oil and lubricate the cylinder (see page 54). *Use gasoline stabilizers that are formulated to extend storage life. Follow the manufacturer’s instructions for use. Contact your authorized Honda generator dealer for stabilizer recommendations.
  • Page 54 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. • Stop the engine and let it cool before handling fuel. • Keep heat, sparks, and flame away. •...
  • Page 55 STORAGE 3. Loosen the carburetor drain screw, and drain the gasoline from the carburetor into a suitable container. CARBURETOR DRAIN SCREW 4. Remove the spark plug maintenance cover, and the spark plug cap (see page 46). 5. Turn the engine switch to the ON position (see page 24). 6.
  • Page 56: Engine Oil

    STORAGE Engine Oil Change the engine oil (see page 41). Engine Cylinder 1. Remove the spark plug (see page 46), and pour approximately one teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug.
  • Page 57: Storage Precautions

    STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer.
  • Page 58: Transporting

    TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
  • Page 59: Taking Care Of Unexpected Problems

    (see page 46). Spark plug wet with fuel Dry and reinstall spark plug. (flooded engine). Fuel filter restricted, carburetor Take the generator to an malfunction, ignition authorized Honda servicing malfunction, valves stuck, etc. dealer, or refer to the shop manual.
  • Page 60: Engine Lacks Power

    (see page 52). gasoline, or refueled with bad Refuel with fresh gasoline gasoline. (see page 38). Fuel filter restricted, carburetor Take the generator to an malfunction, ignition authorized Honda servicing malfunction, valves stuck, etc. dealer, or refer to the shop manual.
  • Page 61: No Power At The Ac Receptacles

    Check the cooling air inlet. Stop and restart the engine. Overload indicator blink. Take the generator to an authorized Honda servicing dealer, or refer to the shop manual. GFCI system activated. • GFCI receptacle (120 V 20 A duplex receptacle): Test GFCI and press the RESET button (see page 27).
  • Page 62: Technical Information

    TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries. Frame serial number: Date purchased:...
  • Page 63: Carburetor Modification For High Altitude Operation

    High altitude performance can be improved by specific modifications to the carburetor. If you always operate your generator at altitudes above 5,000 feet (1,500 meters), have your authorized Honda servicing dealer perform this carburetor modification. This engine, when operated at high altitude with the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life.
  • Page 64: Emission Control System Information

    Carbon monoxide does not react in the same way, but it is toxic. Honda utilizes appropriate air/fuel ratios and other emissions control systems to reduce the emissions of carbon monoxide, oxides of nitrogen, and hydrocarbons.
  • Page 65 Honda cannot deny coverage under the emission warranty solely for the use of non-Honda replacement parts or service performed at a location other than an authorized Honda dealership; you may use comparable EPA certified parts, and have service performed at non- Honda locations.
  • Page 66: Air Index

    TECHNICAL INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines.
  • Page 67: Specifications

    0.024 – 0.028 in (0.6 – 0.7 mm) Refer to page 46. Valve clearance IN: 0.15 ± 0.04 mm See your authorized (cold) EX: 0.20 ± 0.04 mm Honda dealer. Other specifications No other adjustments needed. Specifications are subject to change without notice.
  • Page 68: Wiring Diagram

    TECHNICAL INFORMATION Wiring Diagram...
  • Page 69: Consumer Information

    CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: http://powerequipment.honda.com/dealer-locator Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician.
  • Page 70: Customer Service Information

    CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management.
  • Page 71: Distributor's Limited Warranty

    What American Honda will Repair or Replace Under Warranty: American Honda will repair or replace, at its option, any part that is proven to be defective in material or workmanship under normal use during the applicable warranty time period. Warranty repairs and replacements will be made without charge for parts or labor.
  • Page 72 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
  • Page 73 Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda disclaims any responsibility for loss of time or use of the product, transportation, commercial loss, or any other incidental or consequential damage. Any implied warranties are limited to the duration of this written limited warranty.
  • Page 74: Honda Parts, Accessories, And Apparel

    What American Honda Will Repair or Replace Under Warranty: American Honda will repair or replace, at its option, any Honda Power Equipment parts, accessories, or apparel that are proven to be defective in material or workmanship under normal use during the applicable warranty time period.
  • Page 75 You must, at your expense, take the Honda Power Equipment part, accessory, or apparel, or the Honda Power Equipment on which the accessory or part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
  • Page 76: Emission Control System Warranty

    CONSUMER INFORMATION Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California (models certified for sale in California only) emission regulations. American Honda Motor Co., Inc. provides the emission warranty coverage for engines in the United States and its territories.
  • Page 77 You are responsible for presenting your power equipment engine to a Honda Power Equipment dealer as soon as a problem exists. The emission related warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
  • Page 78 (including durability) could result in denial of coverage. If such a non-Honda replacement part is used in the repair or maintenance of your engine, and an authorized Honda dealer determines it is defective or causes a failure of a warranted part, your claim for repair of your engine may be denied.
  • Page 79 You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours.
  • Page 80 Tubing, fittings, seals, gaskets, and clamps associated with these listed systems. Note: This list applies to parts supplied by Honda and does not cover parts supplied by the equipment manufacturer. Please see the original equipment manufacturer’s emissions warranty for non-Honda parts.
  • Page 81: Initial Use Instructions

    INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 3. With the generator in a level position, remove the oil filler cap. 4.
  • Page 82: Fuel

    INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage.
  • Page 83 INITIAL USE INSTRUCTIONS 2. Add fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (red) on the fuel filter. UPPER LEVEL MARK (RED) FUEL FILTER TETHER Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank.
  • Page 84: Before Operation

    Please Register Your Generator If your dealer did not collect registration information from you, please take a few minutes and register your purchase with Honda. This allows us to contact you with any important updates regarding your generator. Please note registration is not required to obtain warranty service.
  • Page 85: Index

    INDEX AC Applications .................. 32 AC OPERATION................... 30 AIR CLEANER SERVICE ..............43 Air Index ....................64 ARE YOU READY TO GET STARTED?..........20 BEFORE OPERATION..............20, 82 Carbon Monoxide Hazards ..............6 Carburetor Modification for High Altitude Operation...... 61 Check the Engine ................
  • Page 86 GENERATOR SAFETY ................6 GFCI OPERATION CHECK ..............27 Ground Fault Circuit Interrupter (GFCI) Receptacle ......15 Ground Terminal ................16 Honda Parts, Accessories, and Apparel..........72 Honda Publications................67 IMPORTANT SAFETY INFORMATION ..........6 INITIAL USE INSTRUCTIONS ............79...
  • Page 87 INDEX Knowledge ..................20 LED Light Patterns ................19 MAIN AND OUTER FILTERS CLEANING........... 45 MAINTENANCE SAFETY..............36 MAINTENANCE SCHEDULE .............. 37 NO POWER AT THE AC RECEPTACLES..........59 ® Oil Alert Indicator ................18 OPERATION..................22 Operator Responsibility ............... 6 Overload Alarm (Indicator) ..............
  • Page 88 INDEX SAFE OPERATING PRECAUTIONS............ 22 SAFETY LABEL LOCATIONS..............8 Safety Precautions................36 Serial Number Location ..............60 SERVICING YOUR GENERATOR ............35 SPARK ARRESTER SERVICE.............. 48 SPARK PLUG SERVICE............... 46 Special Requirements ................ 34 Specifications..................65 STANDBY POWER ................34 Starter Grip..................
  • Page 89 MEMO...
  • Page 90 MEMO...
  • Page 91: Quick Reference Information

    QUICK REFERENCE INFORMATION Fuel Type Regular unleaded gasoline with an ethanol content of no more than 10% and a pump octane rating of 86 or higher (see page Engine Oil Type SAE 10W-30, API SJ or later (or equivalent), for general use (see page 42) Maximum oil capacity: 14 oz (0.44 L)
  • Page 92 31Z44802 AH 英 00X31-Z44-8020 Printed in Thailand...

This manual is also suitable for:

Eb2200i

Table of Contents