4. Press the RESET button:
• The green indicator will light continuously.
• If the red indicator starts to blink continuously, contact an
authorized Honda generator dealer.
When the RESET button pops out or the green indicator does not lit
during operation:
• Unplug all appliances from the GFCI protected receptacle.
• Press the RESET button.
– If the GFCI cannot be reset, the GFCI is faulty. Contact an
authorized Honda generator dealer.
– If the RESET button extends, this usually indicates a faulty power
tool, appliance, or cord. If that occurs, perform test steps 1
through 4 to verify that the GFCI is in proper working order. If the
GFCI tests correctly, then the fault is likely to be in the power tool,
appliance, or cord.
Repair or replace the faulty power tool, appliance, or cord before
further use.
RESET BUTTON
OPERATION
INDICATOR