  • Page 1 Intelligent Speed Dome Installation Manual Version 1.0.1...
  • Page 2: Table Of Contents

    Table of Contents INTELLIGENT SPEED DOME INSTALLATION ..........1 Installation Preparation ......................... 1 Check Accessories ..........................2 Open the Device ............................ 2 Dial Switch Setup (Analog Speed Dome) ..................3 1.4.1 Initial Setup ............................3 1.4.2 Dial Switch Setup for Intelligent Speed Dome ................3 1.4.3 Baud rate and Parity Setup ......................
  • Page 3 Wall Mount Bracket ..........................13 Hanging Mount Bracket (Length Optional) ..................13 Corner Mount Bracket ......................... 14 Pole Mount Bracket ..........................15 WALL MOUNT BRACKET INSTALLATION ............17 Component Installation ........................17 Installation ............................. 17 3.2.1 Installation Requirements ......................17 3.2.2 Installation Steps ..........................
  • Page 4 Installation ............................. 25 6.1.1 Installation Requirements ......................25 6.1.2 Installation Steps ..........................25 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION ..... 28 APPENDIX Ⅱ ABOUT RS485 BUS ..............29 RS485 Bus Main Feature ........................29 RS485 Bus Transmission Distance ....................29 The Problem in Practical Use ......................
  • Page 5 Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
  • Page 6 Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed  The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate.  The installation engineer or maintenance engineer shall have qualification certificate for work at height.
  • Page 7 Please make sure the produce is secure firmly on the wall or the ceiling. Please turn off the power and unplug the power cable, If there is any smoke, disgusting smell, or noise. Please contact your local retailer or customer service centre for help. All the examination and repair work should be done by the qualified service engineers.
  • Page 8  Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning liquid to clean the shell and then use soft cloth to make it dry.  Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake.
  • Page 9: Intelligent Speed Dome Installation

    1 INTELLIGENT SPEED DOME INSTALLATION 1.1 Installation Preparation Basic Requirement  All installation and operation here should conform to your local electrical safety codes.  Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement.
  • Page 10: Check Accessories

    Refer to appendix 3 for 24VAC power supply device. Refer to appendix 4 for 12VDC power supply device. Please keep all package material well for future use Please keep speed dome package material well in case you need to send it back to your local retailer or manufacturer for maintenance work.
  • Page 11: Dial Switch Setup (Analog Speed Dome)

    Figure 1-2 1.4 Dial Switch Setup (Analog Speed Dome) Remove the bracket component; you can see there are two dial switch buttons on the PTZ mainboard. You can use them to set intelligent speed dome parity, baud rate, address and etc. 1.4.1 Initial Setup ...
  • Page 12: Baud Rate And Parity Setup

    Figure 1-3 1.4.3 Baud rate and Parity Setup It is used to set speed dome Baud rate and parity. 1 and 2 bits are used to set Baud rate while 3 and 4 bits are used to set parity, see Figure 1-4. Figure 1-4 Please refer to the baud rate setup sheet1-1 for detailed information.
  • Page 13: Terminal Matched Resistance Setup

    Address …… ………………………………………………………………… Sheet 1-3 1.4.5 Terminal Matched Resistance Setup The connection mode of device terminal 120Ω resistance is equipped on the power board. There are two connection modes which are shown in Figure 1-6. 120Ω Figure 1-6 The factory default connection mode is shown in Figure 1-7; the jumper (connection board) is plugged into pin2 and pin 3, which means 120Ω...
  • Page 14: Dial Switch Setup (Hdcvi Intelligent Speed Dome)

    1.5 Dial Switch Setup (HDCVI Intelligent Speed Dome) Remove the bracket component; you can see there are two dial switch buttons on the PTZ mainboard. You can use them to set intelligent speed dome address, baud rate, HD/SD video format and etc. 1.5.1 Initial Setup ...
  • Page 15: Speed Dome Address Setup

    Figure 1-10 Please refer to the baud rate setup sheet1-1 for detailed information. Baud rate 9600bps 4800bps 2400bps 1200bps Sheet 1-1 Please refer to the HD/SD video format setup sheet 1-2 for detailed information. HD/SD video format Self-adapt Sheet 1-2 1.5.4 Speed Dome Address Setup Figure 1-11 See Figure 1-5 for address setup.
  • Page 16 120Ω Figure 1-12 The factory default connection mode is shown in Figure 1-13; the jumper (connection board) is plugged into pin2 and pin 3, which means 120Ω resistance is not connected to the device. Figure 1-13 If you want to connect the 120Ω resistance, you have to pull the jumper out of pin 2 and pin 3, and connect to pin 1 and pin 2, then 120Ω...
  • Page 17: Sd Card Installation (Network Speed Dome Module)

    1.6 SD Card Installation (Network Speed Dome Module) Remove the bracket component; open the cover then you can see there is a Micro-SD card slot on the module ISP board (see Figure 1-15). Micro-SD card can be used for data storage. Figure 1-15 1.7 Reset and SD Card Installation (Network Speed Dome) You can see there is a RESET button and Micro-SD card slot on the PTZ mainboard after you...
  • Page 18: Quick Installation Port

    The installation of this section can be applied to analog intelligent speed dome, Network Intelligent Speed Dome and etc. The speed dome has various brackets suitable for different environments. For detailed information, please refer to chapter 1 to chapter 6. Here we are going to install the intelligent speed dome with the analog speed dome wall mount bracket.
  • Page 19: Install The Speed Dome

    Figure 1-18 Note The video port is covered the heat shrink tube of high shrinking ratio. After the video connection, please heat the tube to make sure the video port is damp proof and water proof. 1.8.3 Install the speed dome Step 1 Pull the integration cable and multiple-function composite cable to the wall mount bracket slowly.
  • Page 20 Figure 1-19 Step 4 Please make sure:  The three stainless screws of the quick installation port are firmly secured.  The intelligent speed dome is fixed.  The speed dome is straight.  The safety hook connection is firm. After your installation, the interface is shown as in Figure 1-20.
  • Page 21: Bracket Dimensions

    2 BRACKET DIMENSIONS 2.1 Wall Mount Bracket The wall mount bracket dimensions are shown as below. See Figure 2-1. Figure 2-1 2.2 Hanging Mount Bracket (Length Optional) The hanging mount bracket is shown as below. See Figure 2-2.
  • Page 22: Corner Mount Bracket

    Figure 2-2 Note: The bracket length adjustable range is: 200mm (default) 400mm (optional) You just need to replace the connection pole. 2.3 Corner Mount Bracket The corner mount bracket is shown as below. See Figure 2-3.
  • Page 23: Pole Mount Bracket

    Figure 2-3 2.4 Pole Mount Bracket The pole mount bracket is shown as below. See Figure 2-4.
  • Page 24 Figure 2-4...
  • Page 25: Wall Mount Bracket Installation

    3 WALL MOUNT BRACKET INSTALLATION 3.1 Component Installation Wall mount bracket is shown as below. See Figure 3-1. Figure 3-1 3.2 Installation 3.2.1 Installation Requirements The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 26 Figure 3-2 Step 2 Install the intelligent speed dome in the bracket. See Figure 3-3. Please refer to 1.7 Speed Dome Installation for more details. Figure 3-3...
  • Page 27: Hang Mount Bracket Installation

    4 HANG MOUNT BRACKET INSTALLATION 4.1 Component Installation Hang mount bracket and its components are shown as below. See Figure 4-1. Figure 4-1 4.2 Installation 4.2.1 Installation Requirements The hang mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 28 Figure 4-2 Please note, if the speed dome is installed in the outdoor environments, you need to paste the silica gel on the surface of the connection plate and the ceiling and the cable exit. Step 2 Pull the cable through the connection pole and then secure the connection pole to the connection plate.
  • Page 29 Please note, if the speed dome is installed in the outdoor environments, you need to paste enough Teflon tape at the top screw thread of the connection pole and then turn the connection pole to the connection plate firmly. Step 3 Please refer to chapter 1.6 for detailed information about speed dome installation.
  • Page 30: Corner Mount Bracket Installation

    5 CORNER MOUNT BRACKET INSTALLATION 5.1 Component Installation Corner mount bracket and its components are shown as below. See Figure 5-1. Figure 5-1 5.2 Installation 5.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle.
  • Page 31 Figure 5-2 Step 2 Install speed dome according to Figure 5-3, please refer to 1.7 for more details about speed dome installation.
  • Page 32 Figure 5-3...
  • Page 33: Pole Mount Bracket Installation

    6 POLE MOUNT BRACKET INSTALLATION Pole mount bracket and its components are shown as below. See Figure 6-1. Figure 6-1 6.1 Installation 6.1.1 Installation Requirements The pole mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 34 Figure 6-2 Note: After the installation, please make sure the clamp is firmly secure in case it may result in clamp broken. Step 2 Please refer to chapter 1.7 for detailed information about speed dome installation. See Figure 6-3.
  • Page 35 Figure 6-3...
  • Page 36: Appendix Ⅰ Lightning Proof And Surge Protection

    7 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 6000V, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
  • Page 37: Appendix Ⅱ About Rs485 Bus

    8 APPENDIX Ⅱ ABOUT RS485 BUS 8.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 8.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
  • Page 38: Rs485 Bus Faq

    Figure 8-2 8.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution   Modify host or speed dome setup ; Speed dome Host address(baud rate) and can run self- speed dome address(baud rate)  Switch RS485 positive end and diagnosis but I are not match;...
  • Page 39: Diameter And The Transmission Distance

    9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%.
  • Page 40 Feet(m) 0.8000 1.000 1.250 2.000 38.17 59.63 152.66 24.43(7.45) (11.63) (18.18) (46.53)...
  • Page 41: Appendix Ⅳ The Relationship Between The 12V Dc Cable

    10 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN THE 12V DC CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the 12V DC power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
  • Page 42 Feet(m) 0.8000 1.000 1.250 2.000 38.17 6.11(1.86) 9.54(2.91) 14.91(4.54) (11.63)...
  • Page 43: Appendix Iv Wire Gauge Reference Sheet

    11 APPENDIX IV WIRE GAUGE REFERENCE SHEET Metric bare wire Bare wire cross diameter section (mm) (mm ) 0.050 0.00196 0.060 0.00283 0.070 0.00385 0.080 0.00503 0.090 0.00636 0.100 0.00785 0.110 0.00950 0.130 0.01327 0.140 0.01539 0.160 0.02011 0.180 0.02545 0.200 0.03142 0.230...
  • Page 44 Note  This manual is for reference only. Slight difference may be found in the user interface.  All the designs and software here are subject to change without prior written notice.  All trademarks and registered trademarks are the properties of their respective owners.