IR Intelligent Speed Dome Installation Manual
Version 1.0.2

Advertisement

Table of Contents
loading

Summary of Contents for Dahua DH-SD6AL245U-HNI-IR

  • Page 1 IR Intelligent Speed Dome Installation Manual Version 1.0.2...
  • Page 2: Table Of Contents

    Table of Contents IR INTELLIGENT SPEED DOME INSTALLATION ..........1 Installation Preparation ......................... 1 Check Accessories ..........................2 Open the Device ............................ 2 Dial Switch Setup........................... 2 1.4.1 Dial Switch Address and Function ....................2 1.4.2 Dial Switch Setup ..........................4 1.4.3 Address Setup ...........................
  • Page 3 WALL MOUNT BRACKET INSTALLATION ............15 Component Installation ........................15 Installation ............................. 15 3.2.1 Installation Requirements ......................15 3.2.2 Installation Steps ..........................15 HANG MOUNT BRACKET INSTALLATION ............. 18 Component Installation ........................18 Installation ............................. 18 4.2.1 Installation Requirements ......................18 4.2.2 Installation Steps ..........................
  • Page 4 RS485 Bus Main Feature ........................28 RS485 Bus Transmission Distance ....................28 The Problem in Practical Use ......................28 RS485 Bus FAQ ..........................29 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE ..........30 10 APPENDIX Ⅳ...
  • Page 5 Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
  • Page 6 Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed  The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate.  The installation engineer or maintenance engineer shall have qualification certificate for work at height.
  • Page 7 Please turn off the power and unplug the power cable, If there is any smoke, disgusting smell, or noise. Please contact your local retailer or customer service centre for help. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair.
  • Page 8  Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning liquid to clean the shell and then use soft cloth to make it dry.  Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake.
  • Page 9: Ir Intelligent Speed Dome Installation

    1 IR INTELLIGENT SPEED DOME INSTALLATION 1.1 Installation Preparation Basic Requirement  All installation and operation here should conform to your local electrical safety codes.  Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement.
  • Page 10: Check Accessories

    1.2 Check Accessories Before the installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are includes. 1.3 Open the Device Please open the box and then take out the speed dome. See Figure 1-1. Figure 1-1 Note: There are two types of IR intelligent speed dome which are shown in Figure 1-1, please refer to...
  • Page 11 Open the cover of the speed dome; you can see there are two dial switch buttons on the PTZ mainboard. You can use them to set speed dome address, baud rate and parity. Please refer to Figure 1-2 for the dial switch address. Figure 1-2 1.4.1.2 HDCVI Speed Dome Open the cover of the speed dome;...
  • Page 12: Dial Switch Setup

    Note: When HDCVI intelligent speed dome only uses coaxial control, dial-up and other related RS485 setup don’t have to be conducted. 1.4.2 Dial Switch Setup Users must set the address, Baud rate or HD/SD video mode which is used by the speed dome before controlling it.
  • Page 13: Baud Rate, Parity Setup, Hd/Sd Video Mode Setup

    1.4.4 Baud Rate, Parity Setup, HD/SD Video Mode Setup The functions which need to be set are different for analog speed dome and HDCVI speed dome, which will be introduced respectively. 1.4.4.1 Analog Speed Dome It is used to set speed dome Baud rate and parity. 1 and 2 bits are used to set Baud rate while 3 and 4 bits are used to set parity, see Figure 1-5.
  • Page 14: Terminal Matched Resistance Setup

    1.4.5 Terminal Matched Resistance Setup The connection mode of device terminal 120Ω resistance is equipped on the power board. There are two connection modes which are shown in Figure 1-7. 120Ω Figure 1-7 The factory default connection mode is shown in Figure1-8; the jumper (connection board) is plugged into pin2 and pin 3, which means 120Ω...
  • Page 15: Speed Dome Installation

    Figure 1-10 1.6 Speed Dome Installation Note: The installation of this section can be applied to IR Analog Intelligent and IR Network Intelligent Speed Dome. The speed dome has various brackets suitable for different environments. For detailed information, please refer to chapter 2 to chapter 6. Here we are going to install the analog speed dome with the analog speed dome wall-mounted bracket.
  • Page 16: Cable Connection

    Figure 1-11 1.6.2 Cable Connection  Connect the safety hook of the IR speed dome cover to the hook of the quick installation port.  Connect the reserved integration cable of the wall mount bracket to the corresponding power cable, video/audio cable, RS485 control cable, alarm port, high frequency cable, fiber cable (if necessary) of the multiple-function composite cable of the IR speed dome.
  • Page 17: Install The Speed Dome

    Note The video port is covered the heat shrink tube of high shrinking ratio. After the video connection, please heat the tube to make sure the video port is damp proof and water proof. 1.6.3 Install the speed dome Step 1 Pull the integration cable and multiple-function composite cable to the wall mount bracket slowly.
  • Page 18 Figure 1-14...
  • Page 19: Bracket Dimensions

    2 BRACKET DIMENSIONS 2.1 Wall Mount Bracket The wall mount bracket dimensions are shown as below. See Figure 2-1. Figure 2-1 2.2 Hanging Mount Bracket (Multiple Lengths) The hanging mount bracket is shown as below. See Figure 2-2.
  • Page 20: Corner Mount Bracket

    Figure 2-2 Note: The bracket length setup values are: 200mm (default) 400mm (optional) You just need to replace the connection pole 2.3 Corner Mount Bracket The corner mount bracket is shown as below. See Figure 2-3.
  • Page 21: Pole Mount Bracket

    Figure 2-3 2.4 Pole Mount Bracket The pole mount bracket is shown as below. See Figure 2-4.
  • Page 22 Figure 2-4...
  • Page 23: Wall Mount Bracket Installation

    3 WALL MOUNT BRACKET INSTALLATION 3.1 Component Installation Wall mount bracket is shown as below. See Figure 3-1. Figure 3-1 3.2 Installation 3.2.1 Installation Requirements The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 24 Figure 3-2 Step 2 Install the IR speed dome in the bracket. See Figure 3-3. Please refer to 1.6 Speed Dome Installation for more details.
  • Page 25 Figure 3-3...
  • Page 26: Hang Mount Bracket Installation

    4 HANG MOUNT BRACKET INSTALLATION 4.1 Component Installation Hang mount bracket and its components are shown as below. See Figure 4-1. Figure 4-1 4.2 Installation 4.2.1 Installation Requirements The hang mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 27 Figure 4-2 Please note, if the speed dome is installed in the outdoor environments, you need to paste the silica gel on the surface of the connection plate and the ceiling and the cable exit. Step 2 Pull the cable through the connection pole and then secure the connection pole to the connection plate.
  • Page 28 Please note, if the speed dome is installed in the outdoor environments, you need to paste enough Teflon tape at the top screw thread of the connection pole and then turn the connection pole to the connection plate firmly. Step 3 Please refer to chapter 1.6 for detailed information about speed dome installation.
  • Page 29: Corner Mount Bracket Installation

    5 CORNER MOUNT BRACKET INSTALLATION 5.1 Component Installation Corner mount bracket and its components are shown as below. See Figure 5-1. Figure 5-1 5.2 Installation 5.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle.
  • Page 30 Figure 5-2 Step 2 Install speed dome according to Figure 5-3, please refer to 1.6 for more details about speed dome installation.
  • Page 31 Figure 5-3...
  • Page 32: Pole Mount Bracket Installation

    6 POLE MOUNT BRACKET INSTALLATION Pole mount bracket and its components are shown as below. See Figure 6-1. Figure 6-1 6.1 Installation 6.1.1 Installation Requirements The pole mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
  • Page 33 Figure 6-2 Note: After the installation, please make sure the clamp is firmly secure in case it may result in clamp broken. Step 2 Please refer to chapter 1.6 for detailed information about speed dome installation. See Figure 6-3.
  • Page 34 Figure 6-3...
  • Page 35: Appendix Ⅰ Lightning Proof And Surge Protection

    7 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 6000W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
  • Page 36: Appendix Ⅱ About Rs485 Bus

    8 APPENDIX Ⅱ ABOUT RS485 BUS 8.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 8.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
  • Page 37: Rs485 Bus Faq

    Figure 8-2 8.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution   Modify host or speed dome setup ; Speed dome Host address(baud rate) and can run self- speed dome address(baud rate)  Switch RS485 positive end and diagnosis but I are not match;...
  • Page 38: Diameter And The Transmission Distance

    9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%.
  • Page 39 Feet(m) 0.8000 1.000 1.250 2.000 38.17 59.63 152.66 24.43(7.45) (11.63) (18.18) (46.53)...
  • Page 40: Appendix Ⅳ The Relationship Between The 12V Dc Cable

    10 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN THE 12V DC CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the 12V DC power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
  • Page 41 Feet(m) 0.8000 1.000 1.250 2.000 38.17 6.11(1.86) 9.54(2.91) 14.91(4.54) (11.63)...
  • Page 42: Appendix Iv Wire Gauge Reference Sheet

    11 APPENDIX IV WIRE GAUGE REFERENCE SHEET Metric bare wire Bare wire cross diameter section (mm) (mm ) 0.050 0.00196 0.060 0.00283 0.070 0.00385 0.080 0.00503 0.090 0.00636 0.100 0.00785 0.110 0.00950 0.130 0.01327 0.140 0.01539 0.160 0.02011 0.180 0.02545 0.200 0.03142 0.230...