Page 4
Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
Page 5
Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. The installation engineer or maintenance engineer shall have qualification certificate for work at height.
Page 6
All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair. Note Safety Transportation Heavy stress, violent vibration or water splash are not allowed during transportation, storage and installation.
Page 7
Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake. Do not allow the plastic or rubber material to touch the shell for a long time. It may result in paint flake.
1 INTELLIGENT SPEED DOME INSTALLATION 1.1 Installation Preparation Basic Requirement All installation and operation here should conform to your local electrical safety codes. Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement.
Non-original package material may result in device damage during the transportation. Check Accessories Before the installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are included. 1.2 Initial Setup The default setup is: ...
1.3.2 Baud Rate and Parity The dial switch SW3 is to set speed dome baud rate and parity. It ranges from 1 to 4. The 1 the 2 are to set baud rate. The 3 and the 4 are to set parity. See Figure 1-2. Figure 1-2 Please refer to the baud rate sheet for detailed information.
1.3.4 Terminal Matching Resistance Setup There is terminal resistance 120Ω on the power board. There are two connection modes: See Figure 1-4. 120Ω Figure 1-4 The factory default connection mode is shown as in Figure 1-5. Right now, the jumper on the power board (Connection board) is on the pin 2 and pin 3.
Figure 1-7 SD card of network speed dome should be installed on the module, see Figure 108 for more details. Figure 1-8 Note: Please contact the technical support of our company if you have any questions. 1.5 Installation Installation here includes intelligent analog speed dome, intelligent network speed dome, intelligent auto-tracking speed dome and etc.
Page 13
The speed dome has several types of installation brackets. You can refer to the chapter 3 to chapter 5 for detailed information. Here we are going to install the speed dome in wall mount bracket. Step 1 Remove the package and then take out the device. Step 2 Open the transparent cover and take out the around the speed dome driver.
Page 14
1. Please note you need to check the steel wire of the bracket is firmly secure or not. Please line up the captive screws to the quadrate groove of the bracket and then push the bracket into the internal enclosure. Fix these two captive screws. See Figure 1-11. Figure 1-11 Step 5 Wall Mount Bracket Installation 1.
Page 15
Figure 1-13 Figure 1-14 4. Use the hex wench to fix the other two M6*10 inner hex stainless screws (with spring washer) of the bracket to secure the speed dome. See Figure 1-15.
Page 16
Figure 1-15 After the installation; please use the hex wrench to secure the three M6 stainless screws. Please make sure these three M6 stainless screws are firm so that it can secure the speed dome on the wall mount bracket. Otherwise there is falling risk of the speed dome if these three screws are not in the proper position.
2 BRACKET DIMENSIONS 2.1 Wall Mount Bracket The wall mount bracket dimensions are shown as below. The unit is mm. See Figure 2-1. 4-Ф9 235.00 58.00 Figure 2-1 2.2 Corner Mount Bracket The corner mount bracket is shown as below. The unit is mm. See Figure 2-2.
3 WALL MOUNT BRACKET INSTALLATION 3.1 Component Installation Wall mount bracket is shown as below. See Figure 3-1. Figure 3-1 3.2 Installation 3.2.1 Installation Requirements The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
4 CORNER MOUNT BRACKET INSTALLATION 4.1 Component Installation Corner mount bracket and its components are shown as below. See Figure 4-1. Figure 4-1 4.2 Installation 4.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle.
5 POLE MOUNT BRACKET INSTALLATION 5.1 Installation Components Pole mount bracket and its components are shown as below. See Figure 5-1. Figure 5-1 5.2 Installation 5.2.1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments.
Page 25
Step 2 Please refer to chapter 1.5 for detailed installation information. See Figure 5-3 for the complete installation of Speed dome. Figure 5-3...
6 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 1500W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
7 APPENDIX Ⅱ ABOUT RS485 BUS 7.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω . Its max load amount is 32 effective loads (including main control device and devices to be charged). 7.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
Figure 7-2 7.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution Modify host or speed dome setup ; Speed dome Host address(baud rate) and can run self- speed dome address(baud rate) Switch RS485 positive end and diagnosis but I are not match;...