Maintenance
5. Use the impact wrench fitted with the 9/16" socket to remove the outside mount bolt and inside nut. Do
not discard. See Figure AA.
Figure AA
6. Pull out the handle isolation bracket and remove the old ISO mount bushing. See Figures AB and AC.
Figure AB
Figure AC
7. Install the new ISO mount bushing and ensure the stud faces the inside of the machine. Reverse step 5
to secure the new bushing. Do not overtighten!
8. Reverse steps 4, 3, and 2 to secure the handle.
9. Repeat the entire procedure on the opposite side of the machine to replace both ISO mount bushings.