Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE: Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
Page 8

VENT SYSTEM IDENTIFICATION

*NOTE: If using three
90° elbows during
horizontal termination.
See Figure 30.
Figure 1
When selecting a vent system for use with the fireplace, refer to
the "Special Vent Systems" section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use Figure 22 on page 17 for top venting, or Figure 35 on page
22 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
SPECIAL VENTING COMPONENTS (DURAVENT)
See Empire Comfort Systems Retail Price List for Duravent
part numbers and pricing.
Special DV Vent Kits Available from Empire Comfort Systems,
Inc. dealers.
Direct-Vent Fireplace Vent Kit - Vertical, Includes
DVVK-4VP
SD46DVA-VCH, SD46DVA-F6 and SD46DVA-SC
Direct-Vent Fireplace Vent Kit, Thru-the-wall, for
DVVK-4RE
5 to 13-3/4 inch wall thickness
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-
the-wall, 8 to 11 inch wall thickness, Includes
DVVK-4TP
SD46DVA-HC, SD46DVA-E90,
SD46DVA-09, SD46DVA-08A and SD46DVAWT
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-
the-wall, 5 to 7 inch wall thickness, Includes
DVVK-4TSP
SD46DVA-HC, SD46DVA-E90,
SD46DVA-06 and SD46DVA-WT
Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to
DVVK-5RP
12 inch wall thickness, Includes SD-58DVA06,
SD-58DVAHC, and SD58DVAWTEC
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-
the-wall, 4 to 6 inch wall thickness, Includes
DVVK-5TP
SD58DVAE90, SD58DVAHC,
SD58DVA06, and SD58DVAWTEC
Direct Vent Fireplace Vent Kit - Vertical, Includes
DVVK-5VP
SD58DVAVCH, SD58DVASC, and SD58DVAF6
*DVVK-5F
Horizontal Flex Vent Kit (4' Flex) (1.22m)
*DVVK-4F
Direct-Vent Fireplace Horizontal Flex Vent Kit
*Empire Flex Vent Kits
NOTE: Appliances can use the DVVK-4 Hard Pipe Vent Systems,
only if using a SD58DVA-X46 adaptor.