Troubleshooting - Screen/Leds/Control Panel - Hearth and Home Technologies Outdoor Lifestyles ODLANAIG-48 Owners Manual Care And Operation

Table of Contents

Advertisement

C. Troubleshooting – Screen/LEDs/Control Panel
SYMPTOM
LED Lights will not turn
on (Appliance or Control
Panel)
Appliance does not
turn on when Control
Panel on/off switch is
depressed
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Lanai 48/60 Owner's Manual • 4111-900 Rev. C • 06/21
POSSIBLE CAUSE
Check that GFCI breaker is operating as intended and is
not tripped. Verify that AC power has been connected to
No AC power to
the appliance. Ensure that both the 3V IPI control module
appliance
power supply as well as the LED power supply are securely
plugged into the appliance junction box.
Check appliance for loose/corroded connections or shorted
Faulty Wiring
wires.
Check for 12VDC from power supply. If 12VDC is present,
LED Failure
LED strip is bad.
Check for 12VDC. If no 12VDC is present, power supply is
Power Supply Failure
bad
Control Panel Failure Replace Switch assembly
Check that GFCI breaker is operating as intended and is
not tripped. Verify that AC power has been connected to the
No AC power to
appliance. Ensure that both the 3V IPI control module power
appliance
supply as well as the 12V LED power supply are securely
plugged into the appliance junction box.
Check appliance for loose/corroded connections or shorted
Faulty Wiring
wires.
Control Panel Failure Replace Control Panel
In certain high wind conditions the appliance will shut itself
High temp limit
down to prevent damage to appliance. The appliance will
switch tripped (LP
reset itself as it cools down. To turn appliance back on, cycle
conversion only)
the power switch to off and then on again.
CORRECTIVE ACTION
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor lifestyles odlanaig-60

Table of Contents