Compaq 486 Maintenance And Service Manual page 38

Personal computer
Table of Contents

Advertisement

1719 - 47
Failed to park heads
1719 - 48
Failed to move disk
table to RAM
-----------------------------------------------------------------------------
Error
Code
Description
-----------------------------------------------------------------------------
1719 - 49
Failed to read media in
file write test
1719 - 50
Failed file I/O write test
1719 - 51
Failed file I/O read test
1719 - 52
Failed file I/O compare test
1719 - 53
Failed drive/head
register test
1719 - 54
Failed digital input
register test
1719 - 55
Failed cylinder 1
1719 - 56
Fixed disk drive controller
RAM diagnostics failed
1719 - 57
Fixed disk drive
controller to drive
test failed
1719 - 58
Failed to write sector
buffer
1719 - 59
Failed to read sector
buffer
1719 - 60
Failed to compare sector
buffer
1719 - 61
Failed uncorrectable
Error Correction Code error
-----------------------------------------------------------------------------
Error
Code
Description
-----------------------------------------------------------------------------
1719 - 62
Failed correctable Error
Correction Code error
1719 - 63
Failed soft error rate
1719 - 65
Exceeded maximum
bad sector per track
1719 - 66
Failed initial drive
parameter
1719 - 67
Failed to write long
Recommended
Action
The following steps apply
to error codes 1700 - xx
through 1719 - xx:
1.
Replace the fixed disk
drive and retest.
2.
Replace the power
distribution board
and retest.
3.
Replace the I/O board
and retest.
Recommended
Action
The following steps apply
to error codes 1700 - xx
through 1719 - xx:
1.
Replace the fixed disk
and retest.
2.
Replace the power
distribution board
and retest.
3.
Replace the I/O board
and retest.