211 - xx
Random Pattern Test
211 - 01
Memory random pattern
test failed
211 - 02
Error during saving program
memory and random pattern
in write/read test
211 - 03
Error during restore of
program memory and random
pattern in write/read test
211 - 04
Insufficient memory to
perform test
211 - 05
Inverted pattern compare,
but RAM correct
=============================================================================
Table 3-4.
Keyboard Test Error Codes
=============================================================================
Error
Code
Description
-----------------------------------------------------------------------------
301 - 01
Keyboard short test,
8042 self test failed
301 - 02
Keyboard short test,
interface test failed
301 - 03
Keyboard short test, echo
test failed
301 - 04
Keyboard short test failed
302 - 01
Keyboard long test failed
303 - 01
Keyboard LED test, 8042
self test failed
303 - 02
Keyboard LED test, reset
test failed
303 - 03
Keyboard LED test, reset
test failed
303 - 04
Keyboard LED test, LED
command test failed
303 - 05
Keyboard LED test, LED
command test failed
303 - 06
Keyboard LED test, LED
command test failed
303 - 07
Keyboard LED test, LED
command test failed
Recommended
Action
The following steps apply
to error codes 301 - xx
through 304 - xx:
1.
Check the keyboard
connection.
If
disconnected, turn off
the computer and
connect the keyboard.
2.
Replace the keyboard
and retest.
3.
Replace the I/O board
and retest.