Overview; Evm Set-Up And Precautions; Block Diagram And Sympol™ Signal States - Texas Instruments Sympol SN65HVD96 User Manual

Table of Contents

Advertisement

Overview

1
Overview
The SN65HVD96 is designed for error-free data transmission under wire-fault conditions. The receiver
provides correct output data whether the bus wires are connected normally or cross-wired. This feature is
known as symmetric-polarity ( Sympol™) and is auto-detected internally, so no intervention from the
controller or the operator is required (see
SN65HVD96
1
R
2
RE
3
DE
4
D
Figure 1
shows that Sympol™ signaling is similar but not identical to CAN-bus signaling. Sympol™
transceivers only look at the magnitude of the differential bus voltage, |V
driver output, this voltage is called |V
A Sympol™ bus state is known as passive when |V
Similar to RS-485, Sympol™ transceivers can be used for point-to-point, multi-drop, or multi-point
networks. Current-limited differential outputs protect in case of driver contention on a "party-line" bus. High
receiver input impedance allows the connection of at least 32 nodes. The pin-out is identical to the
industry-standard SN75176 transceiver, thus allowing for a direct upgrade from RS-485 to Sympol™.
Note that Sympol™ signaling does not support the operation of Sympol™ transceivers together with
RS-485 or CAN transceivers in a mixed-transceiver type of network. Only Sympol™ transceivers are able
to communicate between another. However, it is possible to replace an entire RS-485 transceiver network
with Sympol™ transceivers while maintaining the same high-level network protocol without the need for
software changes.
2

EVM Set-up and Precautions

Figure 2
shows the schematic of the SNHVD96 EVM. The board mounts 13 BergStik headers from JMP1
to JMP14 (JMP5 is omitted) and two 3-pin terminal blocks, TB1 and TB2, supporting the device evaluation
for a wide range of system configurations.
Pin 1 (EARTH) is a second ground pin that allows applying an external voltage between GND and
EARTH to simulate common-mode voltage conditions.
Pin 2 (GND) shall be connected to the negative output or ground terminal of the PSU. This pin
represents the ground potential of the device-under-test and the entire EVM. It also connects to
various jumpers on the board.
Pin 3 (VCC) shall be connected to the positive output of a regulated 5V power supply unit (PSU) as it
represents the positive supply voltage of the device-under-test and also connects to various jumpers
on the board.
2
Sympol™ Transceiver
Figure
Driver signaling (DE = high)
D
8
V
CC
7
B
B
V
CM
6
A
A
5
GND
|V
|
OD
Figure 1. Block Diagram and Sympol™ Signal States
|, at a remote receiver input, it becomes |V
OD
Copyright © 2010, Texas Instruments Incorporated
1).
A or B
B or A
|
V
| < 0.5V
|V | > 0.9V
OD
OD
passive
active
A
– V
| < 0.5V, and it is active when |V
A
B
SLLU128A – June 2010 – Revised August 2010
www.ti.com
Receiver detecting(RE = low)
|
V
| < 0.5V
|V | > 0.9V
V
CM
OD
OD
|V
|
passive
active
ID
R
– V
|, not its actual polarity. At a
B
|.
ID
– V
| > 0.9V.
A
B

Advertisement

Table of Contents
loading

Table of Contents