Thermo Scientific Cryofuge 8 Instruction Manual

Thermo Scientific Cryofuge 8 Instruction Manual

Centrifuge and heavy duty centrifuge
Table of Contents

Advertisement

Quick Links

Thermo Scientific
Cryofuge 8 / 16
Centrifuge and Heavy Duty Centrifuge
Instruction Manual
50149611-k
2022-02
Visit us online to register your warranty:
thermofisher.com/labwarranty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cryofuge 8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo Scientific Cryofuge 8

  • Page 1 Thermo Scientific Cryofuge 8 / 16 Centrifuge and Heavy Duty Centrifuge Instruction Manual 50149611-k • 2022-02 Visit us online to register your warranty: thermofisher.com/labwarranty...
  • Page 2: Table Of Contents

    Items Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Intended Use for Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty . . . . . . . . . . . . vii Medical ...........................
  • Page 3 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges 3. 2. Rotor Installation ....................III–3 4 . Maximum Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .III–8 Use of Tubes and Consumables ..................III–9...
  • Page 4 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges 3 . Troubleshooting by Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-3 4 .
  • Page 5 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Table of Figures Figure I–1: Centrifuge clearance, example with bar code scanner ........I–2 Figure I–2: Position of the bubble in the water level ............I–4 Figure I–3: Mains connection on the backside of the centrifuge ........I–5 Figure III–1: Overview centrifuge and rotor, e.g.
  • Page 6 Table I–1: Overview of necessary tools for setting up ............I–3 Table V–1: Error messages ....................V-3 Table A–1: Technical Data Thermo Scientific Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty A–1 Table A–2: Directives, Standards and Guidelines Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty ...........................A–2...
  • Page 7: Preface

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Preface Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers Warranty.
  • Page 8: Medical

    ™ ™ rotor. The Thermo Scientific Cryofuge 16 and Thermo Scientific Cryofuge 16 Heavy Duty centrifuge can be operated with the Thermo Scientific HAEMAFlex 12 and HAEMAFlex 16 rotor. For more details on buckets and further components: [à  2 A–4] [à ...
  • Page 9: Signal Words And Colors

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Signal Words and Colors Signal Word and Color Degree of Hazard WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTI ON Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
  • Page 10 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Risk from handling hazardous substances. Especially when working with corrosive samples (salt solutions, acids, bases), the components and the centrifuge chamber have to be cleaned thoroughly. WARN ING Do not centrifuge explosive or flammable materials or substances.
  • Page 11 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Physical harm caused by ignoring operative basics. Never use the centrifuge if parts of its casing is damaged or missing. Never start the centrifuge when the centrifuge door is open.
  • Page 12: Symbols Used On The Centrifuge And Its Components

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Symbols used on the Centrifuge and its Components This symbol refers to general hazards. Observe the information contained in the instruction manual to keep yourself and your environment safe.
  • Page 13 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Indicates the date after which the device is not to be used. Indicates the manufacturer’s batch code so that the batch or lot can be identified. Indicates the manufacturer’s catalogue number so that the device can be identified.
  • Page 14: Symbols Used In The Manual

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Preface Indicates conformity with Underwriter Laboratories (UL) requirements. Indicates the maximum possible weight of the adapter fully loaded. Indicates the maximum rcf value for centrifugation. Indicates the upper limit of temperature to which the product can be safely exposed to.
  • Page 15: Transport And Set Up

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. Transport and Set Up CA UT I O N Make sure that the centrifuge and the packaging is not damaged. Speak to the shipping company and Thermo Fisher Scientific immediately, if damage is found.
  • Page 16: Transporting

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. Figure I–1: Centrifuge clearance, example with bar code scanner 2. Transporting WARN I N G Never stand before a moving centrifuge to stop it.
  • Page 17: Setting Up

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. 3. Setting Up CAU T I ON Do not push at the touchscreen. Due to the weight of the centrifuge it must be controlled by two or more people when rolling of the pallet. Do not stand in front of the centrifuge when rolling it down the ramp.
  • Page 18: Level The Centrifuge

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. Level the Centrifuge CAU T I ON If you do not level the centrifuge, the centrifuge can crash because of imbalance.
  • Page 19: Mains Connection

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. 4. Mains Connection N OT I C E Connect the centrifuge into grounded electrical sockets only.
  • Page 20: Shipping

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Transport and Set Up THE ACTIVITIES DESCRIBED IN THIS CHAPTER ARE FOR SERVICE TECHNICIANS. 6. Shipping WA R N I N G Before shipping the centrifuge and components you must clean and if necessary, disinfect or decontaminate the full system.
  • Page 21: Thermo Scientific

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Thermo ScientificCentri-Touch User Interface Thermo Scientific Centri-Touch User Interface Actual status information ➀ Set values ➁ Settings and navigation ➂  II–1...
  • Page 22: Status

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Thermo ScientificCentri-Touch User Interface Status The upper part of the touchscreen displays the centrifuge status. The remaining time is indicated while centrifugation is in progress. The progress bar shows the actual phase of the centrifugation.
  • Page 23: Run Parameters

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Thermo ScientificCentri-Touch User Interface Run Parameters The set points for centrifugation can be set in the parameterization window. Clicking one of these buttons will open a new window in which you can input the appropriate set point value.
  • Page 24: Lighthouse Mode

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Thermo ScientificCentri-Touch User Interface Lighthouse Mode If no entry is made via the main screen in 30 seconds, the unit changes to lighthouse mode. In this mode, the status, current values and progress display are displayed larger.
  • Page 25: Operation

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation I I I Operation For detailed instructions and information refer to the separate manual for the Thermo Scientific Centri-Touch User Interface. ™ ™ 1. Switch on the Centrifuge Push the switch at the right side.
  • Page 26: Before Installation

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 3. 1. Before Installation Make sure that all rotor parts are clean, dry and have no nicks and scratches. Always use a rotor body, a windshield bowl and a windshield lid that have the same article number.
  • Page 27: Rotor Installation

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 3. 2. Rotor Installation CAU T I ON An an improper installation of the rotor can cause severe damage to the rotor and the centrifuge. Make sure the rotor is locked properly into place before operating the centrifuge.
  • Page 28: Figure Iii-4: Rotor Locking Tool

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation CA U T I O N The centrifuge drive can be damaged, if the rotor body falls on it. If the rotor body is not engaged correctly it is not possible to turn the rotor locking screw into the drive shaft. Repeat step 3 and 4 until the rotor body is in position.
  • Page 29: Figure Iii-6: Tighten The Rotor To The Drive Shaft

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation Figure III–6: Tighten the rotor to the drive shaft Clean and lubricate the rotor trunnion bolts and the two bolt seats on the sides of each bucket [à  2 IV–3]...
  • Page 30 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation Figure III–8: Install buckets into rotor, e.g. HAEMAFlex 12 When assembling round buckets (75003836/75003936) insert the O-ring below the thread in the bucket. Do not insert it to the bucket lid.
  • Page 31: Figure Iii-10: Correct Loading

    Operation Correct Loading ✓ Figure III–10: Correct Loading Incorrect Loading ✕ Figure III–11: Incorrect Loading Put the windshield lid into the holder at the inner side of the centrifuge door. The Thermo Scientific Auto-Lid function ™ ™ automatically opens and closes the windshield when the centrifuge door opens and closes.
  • Page 32: Maximum Loading

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation Figure III–12: Insert windshield lid into holder CA UT I O N Always put the windshield lid into the holder at the inner side of the centrifuge door. Make sure the rotor is locked properly.
  • Page 33: Use Of Tubes And Consumables

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation Use of Tubes and Consumables Care should be taken to ensure that the tubes and bottles used in the centrifuge are: rated to or above the selected RCF to be spun at, ƒ...
  • Page 34: Runtime Preselection

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation If a speed or RCF-value out of the nominal range has been selected, a message will appear with the N OT I C E permissible values. Explanation of RCF-Value The relative centrifugal force (RCF) is given as a multiple of the force of gravity (g).
  • Page 35: Programs

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 7. Programs For detailed instructions and information refer to the according manual for the Thermo Scientific Centri-Touch User Interface. The instructions stated here are just an extract of how to work with programs. Press on the touchscreen.
  • Page 36: Centrifugation

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 8. Centrifugation WA R N I N G Do not operate the centrifuge on its casters. CA UT I O N An an improper installation of the rotor can cause severe damage to the rotor and the centrifuge.
  • Page 37: Using The Drain Box

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 8. 3. Using the Drain Box You can use the drain box (75007730) to collect water from of the centrifugation chamber. Figure III–14: Drain box (75007730) Install the drain box.
  • Page 38: Remove A Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation Don’t use any sharp tool to extract the plug. This might damage the centrifugation chamber. N OT I C E You have to regularly check, if the drain box is filled and empty the drain box to avoid spilling on the floor.
  • Page 39: Switch Off The Centrifuge

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Operation 10. Switch off the Centrifuge Turn off the power supply switch located on right side of the centrifuge.  III–15...
  • Page 40: Maintenance And Care

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care Maintenance and Care 1. Cleaning Intervals For the sake of personal, environmental and material protection, you must clean and if necessary, disinfect the centrifuge and its components on a regular basis.
  • Page 41: Rotor And Components Inspection

    Press Settings (gears symbol), then Runs and then Rotor Log to see the information. Besides the values of the rotor an information about the number of cycles completed by this rotor type in this centrifuge is shown. For detailed instructions and information refer to the separate manual for the Thermo Scientific Centri-Touch User Interface.  IV–2...
  • Page 42: Cleaning

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 3. Cleaning CAU T I ON Before using any cleaning methods, users should check with the manufacturer of the cleaning agents that the proposed method will not damage the equipment.
  • Page 43: Touchscreen

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care Clean the bucket surfaces and rotor bolts as follows: Cut a cleaning pad (66309) into 12 mm (1/2 inch) wide strips. Saturate one of the pad strips with acetone or alcohol.
  • Page 44: Filter Mat

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 3. 2. Filter Mat CA UT I O N Do not touch the edges of the housing with your hands when the grid is removed. Cutting damage can occur, if you touch the edges due to their sharpness.
  • Page 45: Disinfection

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 4. Disinfection WA R N I N G Do not touch infected parts. Hazardous infection is possible when touching the contaminated rotor and centrifuge parts. Infectious material can get into the centrifuge when a tube breaks or as a result of spills.
  • Page 46: Autoclaving

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 6. Autoclaving CA UT I O N Never exceed the permitted temperature and duration when autoclaving. N OT I C E No chemical additives are permitted in the steam.
  • Page 47: Maintenance

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 7. Maintenance 7. 1. Preventive Maintenance In order to keep this product able to perform the intended application in a reliable and safe state, ongoing preventive maintenance is necessary in accordance with the following recommended schedule: For rotors and buckets mind the information in the Rotor and Components chapter.
  • Page 48: Shipping And Disposal

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Maintenance and Care 8. Shipping and Disposal WA R N I N G When removing the centrifuge and components from use for disposal you have to clean and if necessary, disinfect or decontaminate the entire system.
  • Page 49: Troubleshooting

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Troubleshooting Troubleshooting 1. Mechanical Emergency Door Release WA R N I N G Serious injuries can occur, if you touch a spinning rotor with your hands or tools. A rotor can still be spinning after a power failure occurs.
  • Page 50: Ice Formation

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Troubleshooting Pull out the power supply plug. On both sides of the housing are two white plastic plugs. Get these two white plastic plugs out of both sides of the housing.
  • Page 51: Troubleshooting By Guide

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Troubleshooting 3. Troubleshooting by Guide CA UT I O N If problems occur other than those listed in this table, service technician must be contacted. If an error occurs, follow the instructions on the touchscreen. Error messages have a red colored background.
  • Page 52: Information For The Customer Service

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Troubleshooting 4. Information for the Customer Service If you need to contact a service technician, please provide the order no. and the serial no. of your centrifuge. This information can be found on the back near the inlet for the power supply cable.
  • Page 53: Technical Specifications

    1 m in front of the instrument at 1.6 m height. Without rotor. ³ ³ Applications using temperatures below 25 °C must pre-cool the centrifugation chamber and rotor. Table A–1: Technical Data Thermo Scientific Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty  A–1...
  • Page 54: Directives, Standards And Guidelines

    *Please see Declaration of Compliance which legislation was applied. Table A–2: Directives, Standards and Guidelines Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 55: Refrigerants

    1 397 2.51 t Duty Table A–3: Refrigerants used in the Cryofuge 8 / 16 and Cryofuge 16 Heavy Duty Contains fluorinated greenhouse gases in a hermetically sealed system. 3. Mains Supply The following data is to be taken into consideration, when selecting the mains connection socket.
  • Page 56: Components

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Technical Specifications 4. Components Autoclavable Max. (121 °C, 20 min; Article No. Description Rotor Capacity Max. RCF Speed = no, = yes ✘ ✔ 75007742 Centri-Log Plus ✘ 75007740 Sample Tracking Kit ✘...
  • Page 57: Table A-5: Components

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Technical Specifications Autoclavable Max. (121 °C, 20 min; Article No. Description Rotor Capacity Max. RCF Speed = no, = yes ✘ ✔ 75003855 Hook Adapter for Cord Blood 12 or 16 x 300 ml 1 328 x g ✔...
  • Page 58: Rotors

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors Rotors Items Supplied for Rotors Article No. Item Quantity Rotor (incl. Windshield Bowl and Windshield Lid) 75003861 Thermo Scientific HAEMAFlex 6 75003881 Thermo Scientific HAEMAFlex 8 75003862 Thermo Scientific HAEMAFlex 12...
  • Page 59: Haemaflex 6 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 6 Rotor with Single Blood Bag Buckets (oval) Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity 6 x 1000 ml...
  • Page 60: Table B-3: Haemaflex 6 Rotor With Single Blood Bag Buckets (Round

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 6 Rotor with Single Blood Bag Buckets (round) Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity 6 x 1000 ml...
  • Page 61: Haemaflex 6 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 6 Rotor with Single Blood Bag Buckets with Filter Pack Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity...
  • Page 62: Haemaflex 8 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 8 Rotor with Single Blood Bag Buckets (oval) Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity 8 x 1000 ml...
  • Page 63: Table B-6: Haemaflex 8 Rotor With Single Blood Bag Buckets (Round

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 8 Rotor with Single Blood Bag Buckets (round) Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity 8 x 1000 ml...
  • Page 64: Haemaflex 8 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 8 Rotor with Single Blood Bag Buckets with Filter Pack Technical Data Cryofuge 8 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V Rotor Capacity...
  • Page 65: Haemaflex 12 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 12 Rotor with Double Blood Bag Buckets Technical Data Cryofuge 16 / Cryofuge 16 Heavy Duty 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V...
  • Page 66 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 12 Rotor with Oval Buckets Technical Data Cryofuge 16 / Cryofuge 16 Heavy Duty Centrifuge Voltage 200, 208, 220, 230, 240 V 380, 400, 415 V Rotor Capacity...
  • Page 67: Haemaflex 16 Rotor

    Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 16 Rotor with Double Blood Bag Buckets Technical Data Cryofuge 16 / Cryofuge 16 Heavy Duty 200, 208, 220, Centrifuge Voltage 380, 400, 415 V 230, 240 V...
  • Page 68 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Rotors HAEMAFlex 16 Rotor with Oval Buckets Technical Data Cryofuge 16 / Cryofuge 16 Heavy Duty Centrifuge Voltage 200, 208, 220, 230, 240 V 380, 400, 415 V Rotor Capacity...
  • Page 69 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–1...
  • Page 70 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–2...
  • Page 71 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–3...
  • Page 72 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–4...
  • Page 73 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–5...
  • Page 74 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–6...
  • Page 75 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–7...
  • Page 76 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–8...
  • Page 77 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–9...
  • Page 78 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–10...
  • Page 79 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Chemical Compatibility Chart  C–11...
  • Page 80 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Index Ice Formation Install a Rotor III–1 Intended Use Intended User Items Supplied Acceleration / Deceleration Profiles III–9 Items Supplied for Rotors B–1 Aerosol-tight Rotors III–9 Autoclaving IV–7 Location I–1...
  • Page 81 Thermo Scientific Cryofuge 8 / 16 Centrifuges and Heavy Duty Centrifuges Technical Specifications A–1 Transport and Set Up I–1 Transporting I–2 Troubleshooting V-1, Unpacking I–3 Use of Tubes and Consumables III–9...
  • Page 82 Thermo Scientific Cryofuge 8 / 16 Thermo Scientific Cryofuge 16 Heavy Duty Thermo Electron LED GmbH Zweigniederlassung Osterode Am Kalkberg, 37520 Osterode am Harz Germany thermofisher.com/centrifuge © 2016–2022 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries unless otherwise indicated.

This manual is also suitable for:

Cryofuge 16

Table of Contents