Ac Parallel Terminals - Sportsman GEN351KIT30 Instruction Manual

Invertor generators
Table of Contents

Advertisement

Smart Throttle Control Switch
When the Smart Throttle Control switch is turned to the "ON" position, the economy control unit automatically determines the generator's proper
engine speed based on the connected electronic load. This results in superior fuel economy and reduces noise. When the Smart Throttle switch is
turned to the "OFF" position, the engine runs at the rated speed of 4,100 r/min. Note: The Smart Throttle switch must be turned to the "OFF" position
when using electronic devices that require a large starting current, such as a compressor.

AC PARALLEL TERMINALS

Located just above the RV Outlet, the generator's Parallel Outlets enable a user to run two GEN3500DFI generator's simultaneously. This
operation requires special cables (sold separately).
The parallel port terminals are used with a parallel kit (sold separately). It will allow two generators to be linked to increase output. The black
and white wire connections are non-polarized and can be inserted into either the left or right ports.
NOTE: Do not disconnect cables while the generator is running. The generator or the load may be damaged.
NOTE: Only connect two identical Inverter Generators together using a Parallel Kit.
Do not pair more than 2 generators.
Only use the Sportsman Generator parallel output cable for parallel operation (sold separately).
You can use the outlets on the control panel of the generator while operating in parallel. Do not exceed combined
load on all outlets 20 amps.
If parallel cables are not properly connected to the generators, one or both generators can be damaged and
could explode.
DO NOT connect or disconnect the parallel connection cable from the control panel while the generators are
running. Turn off both generators before disconnecting parallel cables.
Before connecting an appliance to a generator, make sure that the appliance is in good working order and that its electrical rating does not
exceed that of the outlet. Most appliances require more than their electrical rating for startup.
1.
Have both generators ready to operate.
Plug in BOTH parallel cables FIRST. If you attach black wire on left A and white wire on right B, duplicate the same position on the
2.
opposite generator.
Attach both ground connections on both control panels.
3.
4. Power up each generator, with the Smart Throttle switch in off position.
5. After running a few minutes, plug in appliances into RV cable or outlet on control panel. Make sure appliances are off.
6. Gradually turn on each appliance after making sure both generators are in normal running (the output indicator LED (green) flashes.
Note:
The required power of the electrical appliance connected to the parallel outlet cannot exceed the rated output
of paralleled generators.
Item # GEN351KIT30 Invertor Generators
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gen3500df

Table of Contents