Checking The Heat Exchanger Unit; Replacing The Plinth Filter - Miele TWB120WPT1 Operating Instructions Manual

Heat-pump
Table of Contents

Advertisement

Cleaning and care

Checking the heat exchanger unit

Danger of injury! Do not touch
the cooling fins with your hands. You
could cut yourself.
 Look to see if lint has accumulated.
If there is visible soiling:
Clean using a vacuum cleaner
with a dusting brush attached. Only
pass the vacuum cleaner brush over
them lightly, without applying any
pressure. Take care not to bend the
cooling fins out of shape or to
damage them!
 Carefully vacuum up any visible lint or
dirt.
44

Replacing the plinth filter

 Fit the filter back on the handle. Make
sure it is the correct way round.
To ensure that the filter is positioned
correctly in the front of the heat
exchanger unit:
 First insert the handle with the plinth
filter attached over the two guide
pins:
- The word Miele on the handle must
be the correct way up!
 Push the plinth filter in completely.
The act of pushing in the plinth filter will
also push in the right-hand guide pin.
 Close the heat exchanger flap.