Thermostat Adjustment
The thermostat controls the water temperature in the tank. Factory setting is 195 degrees F. This
is the ideal temperature for brewing coffee. Water should never boil in the tank. If water is
boiling in the tank, adjust the temperature appropriately.
Standard Mechanical Thermostat:
1)
Shut off power and unplug brewer.
2)
Open cover, locate thermostat mounted on tank. (Refer to Figure B).
3)
Turn the shaft counter clockwise to increase temperature,
clockwise to decrease temperature.
4)
If the maximum temperature adjustment needs to be increased,
insert a small flat screwdriver into the shaft.Turn the calibration
screw counter clockwise to increase the maximum temperature.
5)
Reinstall top cover with screw then plug unit in, return to use.

Cleaning

WARNING: BURN HAZARD
!
HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT. TO
AVOID BURNS, USE CAUTION WHEN CLEANING. RINSE HOT PARTS
WITH COLD WATER BEFORE CLEANING. USE GLOVES OR A HEAVY
CLOTH WHEN REMOVING HOT PARTS FROM BREWER.
After Each Brew:
1)
Dispose of grounds and rinse brew basket.
2)
Rinse Shuttles and Airpots before reuse.
Every Day:
1)
Wash brew basket with warm soapy water.
2)
Remove spray head located above brew basket, using gloves or a heavy towel. Wash off coffee
oils and clean any plugged holes.
3)
Clean Shuttles and Airpots with warm soapy water and a brush or towel.
4)
Wipe exterior of brewer with a damp cloth. Do not use abrasives which will scratch surface.
5)
If the Shuttle is to be left on the warmer all night, fill it with water to avoid coffee oil burn-in.
P200/RAPS200 Brewers