Porter-Cable CPLKC7080V2-1 Instruction Manual page 25

Oil lube two stage air compressor
Table of Contents

Advertisement

PROBLEM
Knocking Noise. Possible defect in safety
Excessive belt
wear.
Squealing
sound.
CAUSE
valve.
Defective check valve.
Loose pulley.
Loose flywheel.
Compressor mounting
screws loose.
Loose belt.
Carbon build-up in pump.
Belt to tight.
Loose belt.
Tight belt.
Loose pulley.
Pulley misalignment.
Compressor pump has no
oil.
Loose belt.
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Remove and clean, or replace.
Tighten pulley set screw,
145-165 in.-lbs.
Tighten flywheel screw,
33-37 ft.-lbs.
Tighten mounting screws,
20-25 ft.-lbs.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section.
Have checked by a Trained
Service Technician.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section.
Have checked by a Trained
Service Technician.
See Motor Pulley/Flywheel
Alignment paragraph in the
Maintenace section.
See Oil-Checking paragraph in
the Maintenace section.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section.
25-ENG
CORRECTION
D22944

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cplkc7080v2

Table of Contents