Porter-Cable CPLKC7080V2-1 Instruction Manual page 12

Oil lube two stage air compressor
Table of Contents

Advertisement

Use pipe that is the same size as
the air tank outlet. Piping that is
too small will restrict the flow of
air.
If piping is over 100 feet long,
use the next larger size.
Bury underground lines below
the frost line and avoid pockets
where condensation can gather
and freeze. Fill lines with air pres-
sure before covering to make
sure pipe joints are free from
leaks.
AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.
LUBRICATOR
MOISTURE
SEPARATOR
AND TRAP
DIRT
LEG
TYPICAL COMPRESSED
AIR DISTRIBUTION SYSTEM
D22944
FEEDER LINES SLOPE
WITH AIR FLOW
REGULATOR
DRAIN
TRAP
Install a flexible coupling
between the air discharge outlet
and main air distribution line to
allow for vibration.
NOTE: The shut-off valve is not sup-
plied with this unit. You must purch-
sase the shut-off valve separately.
A separate regulator is recom-
mended to control the air pres-
sure. Air pressure from the air
tank is usually too high for indi-
vidual air driven tools.
AIR FLOW
AIR USAGE
LINES
DIRT
LEG
FILTER
FLEXIBLE
COUPLING
AIR DISCHARGE
VALVE
DRAIN COCK
VALVE
12-ENG
DRAIN
LEGS
DRAIN
TRAPS
REGULATOR
LUBRICATOR
AIR
COMPRESSOR