What To Do If - Zanussi ZGG65414SA User Manual

Table of Contents

Advertisement

ing and check that the burner crown holes are
not obstructed.

What to do if...

Problem
There is no spark when lighting
the gas
The flame is blow out immediately
after ignition
The gas ring burns unevenly
www.zanussi.com
Periodic maintenance
Periodically speak your local Service Force
Centre to check the conditions of the gas sup-
ply pipe and the pressure adjuster, if fitted.
Possible cause
• There is no electrical supply
• Burner cap and crown are
placed uneven
• Thermocouple is not heated
sufficient
• Burner crown is blocked with
food residues
Remedy
• Make sure that the unit is con-
nected and the electrical supply
is switched on.
• Control the fuse. If the fuse is
released more than one time,
refer to a qualified electrician.
• Make sure that the burner cap
and crown are in correct posi-
tions.
• After lightning the flame, keep
the knob pushed for approxi-
mately 5 seconds.
• Make sure that the injector is
not blocked and the burner
crown is clear of food particles.
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zgg65414

Table of Contents