DIP Switch Setup in the Connection Unit
Verify that the DIP switches on the Connection Unit are set as described in the following table, according 
to the components used in the system (see Figure 24):
 
In Connection Unit with two DIP switches:
l
Hardware configuration
Auto-transformer with connected over-temperature
sensor
No auto-transformer, or auto-transformer with over-
temperature sensor not connected
 
In Connection Unit with three DIP switches:
l
Hardware configuration
Auto-transformer with connected
over-temperature sensor
No auto-transformer, or auto-
transformer with over-temperature
sensor not connected
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
DIP switch 1
(leftmost) setup
ON ( up ) - default
ON ( up ) - default
Figure 24: Connection Unit DIP switches
Chapter 6: StorEdge Inverter Connections
Left DIP switch
Right DIP switch
(SW1) setup
ON ( up ) - default
OFF (down) - default
ON ( up ) - default
DIP switch 2
(center) setup
(rightmost) setup
ON ( up ) - default
ON ( up ) - default
(SW2) setup
ON ( up )
DIP switch 3
OFF (down) - default
ON ( up )
39