F5 Disposal Of Packing; F6 Plumbing Connections; F6.1 Plumbing Circuits; Figure 10 Feed Pipe Connection - Electrolux EHT8G Manual

Table of Contents

Advertisement

Accessing the appliance bottom panel.
Fit the clamps on feet as shown in supplied techni-
cal sheet.
Screw the appliance steadily to the floor using hole
clamps.
F5
Disposal of packing
All materials used for packing are environmentally
compatible. They can be safely kept, and recycled or
burnt in a special waste incineration plant. Plastic parts
subject to possible recycling are marked as follows:
polyethylene:
PE
polypropylene:
PP
polystyrene
foam:
PS
Parts in wood and cardboard can be disposed of
respecting the current regulations in the country of
use.
F6
Plumbing connections
IMPORTANT
Watermark labelled machines must be installed in
accordance with AS/NZS 3500.1 and drainage to be
in accordance with 3500.2. On models with ESD,
an approved dual check valve must be installed
upstream.
Install the machine water filling and drain pipes accord-
ing to the plumbing circuit and installation diagrams
given below.
Connect the appliance water supply pipe "WI" (see
paragraph F6.2 Installation diagrams) to the mains,
fitting a cut-off cock, the filter provided and a pres-
sure gauge between the appliance and the mains
(Figure 10).
!

Figure 10 Feed pipe connection

Check that the dynamic water supply pressure,
measured between the appliance and the main, is
between 50 and 700 kPa (test while dishwasher
tank or boiler is filling with water).
If the pressure is too high, fit a suitable pres-
sure reducer on the inlet pipe.
14
outer wrapping, instruc-
tion booklet bag.
roof packing panels,
straps.
corner protectors.
Connect the waste outlet pipe "D" (see pargraph
F6.2 Installation diagrams) to the main drain pipe,
fitting a trap, or place the outlet pipe over an S trap
set into the floor.
F6.1
Plumbing circuits
Plumbing circuit diagram - manual hood type
without drain pump
LEGEND
WI =
Water inlet
CWI = Cold water inlet (~ 15°C)
M1 =
Wash pump
M3 =
Rinse pump
M4 =
Drain pump
M9 =
ESD fan motor
M10 = ESD fan motor
AG =
Air Gap
YV1 = Filling solenoid valve
V =
Ventilation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents