Extraction Hood; Disposal Of Packing; Plumbing Connections - Electrolux EHT8 Installation And Operating Manual

Hood dishwasher
Hide thumbs Also See for EHT8:
Table of Contents

Advertisement

• Carefully remove the protective film from the outer panels
without tearing it, to avoid leaving traces of glue.
• Adjust the equipment by turning the special adjustable feet
and making sure it is perfectly level, both length wise and
crosswise.
• The appliance must be fixed to the floor using the two
clamps supplied.
– Accessing the appliance bottom panel.
– Fit the clamps on feet as shown in supplied technical
sheet.
– Screw the appliance steadily to the floor using hole
clamps.
E.6

Extraction hood

For models without Energy Saving Device (ESD), make sure
to install an extractor hood to remove the steam produced by
the machine.
For models with Energy Saving Device (ESD), it is not
necessary to install an extractor hood unless the current
regulations in the country of use require it.
The hood air flow must be calculated taking into account the
type of installation and the work environment where it is
installed.
In any case, an air flow rate of between 1000 m
m
3
/h is recommended.
E.7
The packing must be disposed of in compliance with the
current regulations in the country where the appliance is used.
All the packing materials are environmentally friendly.
They can be safely kept, recycled or burned in an appropriate
waste incineration plant. Recyclable plastic parts are marked
as follows:
The parts in wood and cardboard can be disposed of,
respecting the current regulations in the country where the
machine is used.
E.8
• Connect the appliance water supply pipe "WI" (see the
Installation diagram) to the mains, fitting a cut-off tap, the
filter provided and a pressure gauge between the appliance
and the mains (see figure below).
• Check that the dynamic water supply pressure, measured
between the appliance and the main, is between between
50 and 700 kPa [0.5 - 7 bar] (test while dishwasher tank or
boiler is filling with water).
• On the model with free-fall drainage:
connect the waste outlet pipe (detail "D" in the Installation
diagram) to the main drain pipe, fitting a trap, or place the
outlet pipe over an "S" trap set into the floor.
• On the model with drain pump:
position the outlet pipe at a height anywhere between 750
and 1000 mm from the floor. Check that about 3 litres of
water flow out of the outlet pipe during the rinse cycle.
3
/h and 1500

Disposal of packing

Polyethylene
• Outer wrapping
• Instructions bag
Polypropylene
• Straps
Polystyrene foam
• Corner protectors

Plumbing connections

!
NOTE!
If the pressure is too high, fit a suitable pressure
reducer on the inlet pipe.
CAUTION
Always use a new set of joints if you
remove and reinstall the water inlet pipe to
the appliance.
IMPORTANT
Watermark labelled appliances must be installed in
accordance with AS/NZS 3500.1 and drainage to
be in accordance with 3500.2. On models with ESD,
an approved dual check valve must be installed
upstream.
21