SC825M(B) Chassis Manual
4-2
Control Panel Buttons
The chassis includes two push-buttons that control power to the system.
Reset: The reset button is used to reboot the system.
Power: The main power switch is used to apply or remove power from the power
supply to the server system. Turning off system power with this button removes the
main power but keeps standby power supplied to the system. Therefore, you must
unplug system before servicing.
4-3
Control Panel LEDs
There are six LEDs that provide status information about the system.
!
Power Failure: When flashing, this LED indicates a power supply failure.
Information LED: Alerts operator of several states, as noted in the table below.
Status
Continuously on and red
Blinking red (1Hz)
Blinking red (0.25Hz)
Solid blue
Blinking blue
Information LED
An overheat condition has occurred.
(This may be caused by cable congestion.)
Fan failure, check for an inoperative fan.
Power failure, check for a non-operational power supply.
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Remote UID is on. Use this function to identify the
server from a remote location.
4-2
Description