Overview: Installation - Daikin Altherma EDLQ011-016CW1 Installer's Reference Manual

Low temperature monobloc
Hide thumbs Also See for Altherma EDLQ011-016CW1:
Table of Contents

Advertisement

Item
Description
9
Interconnection cable
for the domestic hot
water pump (between
outdoor unit and control
box)
10
Interconnection cable
for the space heating/
cooling operation
control (or shut‑off
valve) (between
outdoor unit and control
box)
11
Interconnection cable
for valve kit
EKMBHBP1 (between
outdoor unit and control
box)
User interface
12
User interface
Optional equipment
13
Preferential kWh rate
power supply (voltage-
free contact)
14
Domestic hot water
pump
15
Space heating/cooling
operation control (or
shut‑off valve)
16
3‑way valve
17
Power supply for
booster heater and
thermal protection
(from control box)
18
Power supply for
booster heater (to
control box)
19
Domestic hot water
tank thermistor
20
Room thermostat/heat
pump convector
21
Valve kit EKMBHBP1
(a)
Cable section 2.5 mm².
(b)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
20 m.
(c)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
500 m. Applicable for both single user interface and dual
user interface connection.
(d)
Minimum cable section 0.75 mm².
(e)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
50 m. Voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
(f)
The thermistor and connection wire (12 m) are delivered
with the domestic hot water tank.
(g)
If valve kit EKMBHBP1 is part of the system, then the
required cable section is 0.75 mm². If valve kit EKMBHBP1
is NOT part of the system, then the minimum required
cable section is 0.75 mm², and the maximum cable length
is 10 m.
(h)
Cable section 0.75 mm².
(i)
The valve and connection wire (12 m) are delivered with
the valve kit.
(j)
If valve kit EKMBHBP1 is part of the system, then the
required cable section is 0.75 mm². If valve kit EKMBHBP1
is NOT part of the system, then the required cable section
is 1.5 mm².
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522034-1 – 2018.01
Wires
Maximum
running
current
(d)
2
(j)
2
(h)
3 (of which 2 are
shared with those
of item 10)
(c)
2
(e)
2
(d)
2
(k)
2
(f)
3
(a)
4+GND
2+GND
13 A
(f)
2
(g)
3 or 4
100 mA
(i)
3
(k)
If valve kit EKMBHBP1 is part of the system, then the
required cable section is 0.75 mm². If valve kit EKMBHBP1
is NOT part of the system, then the minimum required
cable section is 0.75 mm².
Backup heater kit
Item
Description
Power supply
22
Backup heater power
supply
Interconnection cable
23
Interconnection cable
between backup heater
kit and control box
(a)
Minimum cable section 0.75 mm²; maximum length: 10 m.
Backup heater
Power supply
EKMBUHCA3V3 1× 230 V
EKMBUHCA9W1 1× 230 V
3× 400 V
Option box
Item
Description
Power supply
24
Power supply for option
box
Interconnection cable
25
Interconnection cable
between option box
and control box
Optional equipment
26
Remote indoor sensor
Field-supplied components
27
Electric meter
28
Alarm output
29
Space cooling/heating
ON/OFF output
30
Changeover to external
heat source
(a)
Cable section 2.5 mm².
(b)
Minimum cable section 0.75 mm².
NOTICE
▪ More
technical
connections are indicated on the inside of the units
(outdoor unit, control box, option box and backup
heater).
▪ For how to connect the electrical wiring to the outdoor
unit (and if part of the system, the control box, option
box, and backup heater), refer to
electrical wiring" on
7
Installation
7.1

Overview: Installation

This chapter describes what you have to do and know on-site to
install the system.
7 Installation
Wires
Maximum
running
current
See table below. —
(a)
6 (3V3)
7 (6V3, 6W1,
9W1)
Required number of
conductors
2+GND
2+GND+2 bridges
4+GND
Wires
Maximum
running
current
(a)
2+GND
(b)
3 (max 3 m)
(b)
2
(b)
2 (per meter)
(b)
2
(b)
2
(b)
2
specifications
of
the
different
"7.8  Connecting the
page 40.