Code
[A.2.3.3]
[6-04]
BUH: step 2: Only applies to a two-step
backup heater (*9W). The capacity
difference between the second and first
step of the backup heater at nominal
voltage. Nominal value depends on the
backup heater configuration. Default:
0 kW.
▪ 3 kW, 1N~ 230 V: 0 kW
▪ 6 kW, 1N~ 230 V: 3 kW (6 kW-3 kW)
▪ 6 kW, 3N~ 400 V: 3 kW (6 kW-3 kW)
▪ 9 kW, 3N~ 400 V: 6 kW (9 kW-3 kW)
Range: 0~10 kW (in steps of 0.2 kW)
8.2.5

Space heating/cooling control

The basic required settings in order to configure the space heating/
cooling of your system are described in this chapter. The weather-
dependent installer settings define the parameters for the weather-
dependent operation of the unit. When weather-dependent operation
is active, the water temperature is determined automatically
depending on the outdoor temperature. Low outdoor temperatures
will result in warmer water and vice versa. During weather-
dependent operation, the user has the possibility to shift up or down
the target water temperature by a maximum of 5°C.
See the user reference guide and/or operation manual for more
details about this function.
Leaving water temperature: Main zone
#
Code
[A.3.1.1.1]
N/A
LWT setpoint mode:
▪ 0 (Fixed)
The
temperature is:
▪ NOT weather-dependent (i.e. does
▪ fixed in time (i.e., NOT scheduled)
▪ 1 (Weather dep.) (default): The
desired leaving water temperature is:
▪ weather-dependent (i.e. depends
▪ fixed in time (i.e., NOT scheduled)
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522034-1 – 2018.01
Description
Description
desired
leaving
water
NOT
depend
on
the
outdoor
ambient temperature)
on
the
outdoor
ambient
temperature)
continued >>
#
Code
[A.3.1.1.1]
N/A
<< continuation
▪ 2 (Fixed/scheduled): The desired
leaving water temperature is:
▪ NOT
▪ according
▪ 3
leaving water temperature is:
▪ weather-dependent
▪ according
#
Code
[7.7.1.1]
[1-00]
Set weather-dependent heating:
T t
[1-01]
[1-02]
[1-02]
[1-03]
[1-03]
▪ T
t
(main)
▪ T
a
8 Configuration
Description
weather-dependent
(i.e.,
does NOT depend on the outdoor
ambient temperature)
a
schedule.
scheduled
actions
consists
desired shift actions, either preset
or custom.
Remark: This value can only be
set in leaving water temperature
control.
(WD/scheduled):
The
desired
(i.e.,
does
depend on the outdoor ambient
temperature)
a
schedule.
scheduled
actions
consists
desired
leaving
water
temperatures
either
preset
custom.
Remark: This value can only be
set in leaving water temperature
control.
Description
[1-00]
[1-01]
: Target leaving water temperature
: Outdoor temperature
continued >>
Installer reference guide
The
of
The
of
or
T a
57