4.3.3

Possible options for the control box

User interface (EKRUCBL*)
The user interface and a possible additional user interface are
available as an option.
The additional user interface can be connected:
▪ To have both:
▪ control close to the control box,
▪ room thermostat functionality in the principal space to be
heated.
▪ To have an interface containing other languages.
Following user interfaces are available:
▪ EKRUCBL1 contains following languages: German, French,
Dutch, Italian.
▪ EKRUCBL2 contains following languages: English, Swedish,
Norwegian, Finnish.
▪ EKRUCBL3 contains following languages: English, Spanish,
Greek, Portuguese.
▪ EKRUCBL4 contains following languages: English, Turkish,
Polish, Romanian.
▪ EKRUCBL5 contains following languages: German, Czech,
Slovenian, Slovakian.
▪ EKRUCBL6 contains following languages: English, Croatian,
Hungarian, Estonian.
▪ EKRUCBL7 contains following languages: English, German,
Russian, Danish.
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see
interface" on
page 42.
INFORMATION
▪ If control box EKCB07CAV3 is NOT part of the system,
connect the user interface directly to the outdoor unit.
▪ If control box EKCB07CAV3 is part of the system, you
can also connect the user interface to the control box.
Simplified user interface (EKRUCBS)
▪ The simplified user interface can only be used in combination with
the main user interface.
▪ The simplified user interface acts as room thermostat and needs
to be installed in the room that you want it to control.
For installation instructions, see the installation and operation
manual of the simplified user interface.
Room thermostat (EKRTWA, EKRTR1, RTRNETA)
You can connect an optional room thermostat to control box
EKCB07CAV3. This thermostat can either be wired (EKRTWA) or
wireless (EKRTR1 and RTRNETA). Thermostat RTRNETA can only
be used in heating-only systems.
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522034-1 – 2018.01
"7.8.6  To connect the user

5 Application guidelines

PC configurator (EKPCCAB)
The PC cable makes a connection between the switch box of the
outdoor unit (or that of control box EKCB07CAV3) and a PC. It gives
the possibility to upload different language files to the user interface,
and parameters to the outdoor unit. For the available language files,
contact your local dealer.
The software and corresponding operating instructions are available
on
http://www.daikineurope.com/support-and-manuals/software-
downloads/.
For installation instructions, see the installation manual of the PC
cable, the
"8 Configuration" on page 50
book for optional equipment.
LAN adapter for smartphone control + Smart Grid applications
(BRP069A61)
You can install this LAN adapter to:
▪ Control the system via a smartphone app.
▪ Use the system in various Smart Grid applications.
For installation instructions, see the installation manual of the LAN
adapter.
INFORMATION
▪ If control box EKCB07CAV3 is NOT part of the system,
connect the LAN adapter directly to the outdoor unit.
▪ If control box EKCB07CAV3 is part of the system, you
can also connect the LAN adapter to the control box.
LAN adapter for smartphone control (BRP069A62)
You can install this LAN adapter to control the system via a
smartphone app.
For installation instructions, see the installation manual of the LAN
adapter.
INFORMATION
▪ If control box EKCB07CAV3 is NOT part of the system,
connect the LAN adapter directly to the outdoor unit.
▪ If control box EKCB07CAV3 is part of the system, you
can also connect the LAN adapter to the control box.
4.3.4

Possible options for the option box

Remote indoor sensor (KRCS01-1)
By default the internal user interface sensor will be used as room
temperature sensor.
As an option the remote indoor sensor can be installed to measure
the room temperature on another location.
The
remote
indoor
sensor
EK2CB07CAV3. For installation instructions, see the installation
manual of the remote indoor sensor and the addendum book for
optional equipment.
INFORMATION
▪ The remote indoor sensor can only be used in case the
user interface is configured with room thermostat
functionality.
▪ You can only connect either the remote indoor sensor
or the remote outdoor sensor.
5
Application guidelines
5.1

Overview: Application guidelines

The purpose of the application guidelines is to give a glance of the
possibilities of the Daikin heat pump system.
chapter, and the addendum
is
connected
to
option
box
Installer reference guide
13