Table of Contents

Advertisement

4/10
Field settings table
Breadcrumb Field code
Setting name
└─ WD curve
5.C
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
5.C
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
5.C
[0-0D]
High ambient temp. for DHW WD curve.
5.C
[0-0E]
Low ambient temp. for DHW WD curve.
Tank
5.D
[6-01]
Margin
User settings
└─ Quiet
7.4.1
Activation
└─ Electricity price
7.5.1
High
7.5.2
Medium
7.5.3
Low
User settings
7.6
Gas price
Installer settings
└─ Configuration wizard
└─ System
9.1
[E-03]
BUH type
9.1
[E-05]
Domestic hot water
[E-06]
[E-07]
9.1
[4-06]
Emergency
9.1
[7-02]
Number of zones
└─ Backup heater
9.1
[5-0D]
Voltage
9.1
[4-0A]
Configuration
9.1
[6-03]
Capacity step 1
9.1
[6-04]
Additional capacity step 2
└─ Main zone
9.1
[2-0C]
Emitter type
9.1
[C-07]
Control
9.1
Setpoint mode
9.1
Schedule
9.1
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
9.1
[1-01]
High ambient temp. for LWT main zone heating WD curve.
9.1
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
9.1
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
9.1
[1-06]
Low ambient temp. for LWT main zone cooling WD curve.
9.1
[1-07]
High ambient temp. for LWT main zone cooling WD curve.
9.1
[1-08]
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
9.1
[1-09]
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
└─ Additional zone
9.1
[2-0D]
Emitter type
9.1
Setpoint mode
9.1
Schedule
9.1
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
9.1
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
9.1
[0-02]
High ambient temp. for LWT add zone heating WD curve.
9.1
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
9.1
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
4P556072-1 - 2018.12
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/W
R/W (*1)
R/O (*2)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
35~[6-0E]°C, step: 1°C
55°C
45~[6-0E]°C, step: 1°C
60°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-10°C
0~10°C, step: 1°C
2°C
0: OFF
1: Quiet
2: More quiet
3: Most quiet
4: Automatic
0,00~990/kWh
1/kWh
0,00~990/kWh
1/kWh
0,00~990/kWh
1/kWh
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
3: 6V (*1)
4: 9W (*2)
No DHW (*3)
EKHW (*3)
Integrated (*4)
EKHWP (*3)
0: Manual
1: Automatic
0: Single zone
1: Dual zone
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V, 3~ (*2)
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emergency
0~10kW, step: 0,2kW
2kW (*1)
3kW (*2)
0~10kW, step: 0,2kW
4kW (*1)
6kW (*2)
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: LWT control
1: Ext RT control
2: RT control
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
0: No
1: Yes
-40~5°C, step: 1°C
-10°C
10~25°C, step: 1°C
15°C
[9-01]~[9-00], step: 1°C
35°C
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
10~25°C, step: 1°C
20°C
25~43°C, step: 1°C
35°C
[9-03]~[9-02]°C, step: 1°C
22°C
[9-03]~[9-02]°C, step: 1°C
18°C
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
0: No
1: Yes
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
[9-05]~[9-06]°C, step: 1°C
50°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-10°C
[9-07]~[9-08]°C, step: 1°C
8°C
Installer setting at variance with
default value
Date
Value
(*1) *6V_(*2) *9W_
(*3) *AB*_(*4) EAV*_
(*5) *X*_(*6) *H*_