Daikin Altherma EPGA011-016DV Installer's Reference Manual page 81

Low temperature split
Hide thumbs Also See for Altherma EPGA011-016DV:
Table of Contents

Advertisement

Error code
Detailed error
code
H9
00
HC
00
HJ
10
HJ
11
HJ
12
J3
00
J5
00
J6
00
J6
07
J6
32
J6
33
J7
12
J8
00
J8
07
JA
00
JA
17
L1
00
L3
00
L4
00
L5
00
L8
00
L9
00
LC
00
P1
00
P3
00
P4
00
PJ
00
U0
00
U1
00
U2
00
U3
00
U4
00
U5
00
EPGA11~16DAV3 + EABH/X16DA6V+9W
Daikin Altherma – Low temperature split
4P556069-1 – 2018.10
Description
OU: Malfunction of outdoor air
thermistor
Tank temperature sensor
problem
Water pressure sensor
abnormality
Boiler abnormality detection
Bypass valve turning error
OU: Malfunction of discharge
pipe thermistor
Malfunction of suction pipe
thermistor
OU: Malfunction of heat
exchanger thermistor
OU: Malfunction of heat
exchanger thermistor
Leaving water temperature
thermistor Abnormality (outdoor
unit)
Sensor communication error
Brine inlet thermistor abnormality
Malfunction of refrigerant liquid
thermistor
Brine outlet thermistor
abnormality
OU: Malfunction of high pressure
sensor
Refrigerant pressure sensor
abnormality
Malfunction of INV PCB
OU: Electrical box temperature
rise problem
OU: Malfunction of inverter
radiating fin temperature rise
OU: Inverter instantaneous
overcurrent (DC)
Malfunction triggered by a
thermal protection in the inverter
PCB
Prevention of compressor lock
Malfunction in communication
system of outdoor unit
Open-phase power supply
imbalance
Abnormal direct current
OU: Malfunction of radiating fin
temperature sensor
Capacity setting mismatch
OU: Shortage of refrigerant
Malfunction by reverse phase/
open-phase
OU: Defect of power supply
voltage
Under floor heating screed dryout
function not completed correctly
Indoor/outdoor unit
communication problem
User interface communication
problem
Error code
Detailed error
code
U6
36
U7
00
U8
01
U8
02
U8
03
U8
04
U8
05
U8
06
U8
07
U8
08
UA
00
UA
17
UA
21
UA
22
UA
52
UF
00
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to
program the start-up of the disinfection function at least
4  hours later than the last expected large hot water
tapping. This start-up can be set by installer settings
(disinfection function).
▪ When the Domestic hot water > Type > Scheduled only
is selected, it is recommended to program a Storage
eco 3  hours before the scheduled start-up of the
disinfection function to preheat the tank.
NOTICE
When the minimum water flow is lower than described in
the table below, the unit will temporarily stop operation and
the user interface will display error 7H‑01. After some time,
this error will reset automatically and the unit will resume
operation.
INFORMATION
Error AJ-03 is reset automatically from the moment there is
a normal tank heat-up.
INFORMATION
In case of an E7‑62 error, brine pump operation stops due
to not enough flow in the brine circuit. If 10‑day brine pump
operation is running, it will stop running and will only
resume once the error is reset. It is only possible to reset
the error with the domestic hot water home screen or the
leaving water temperature home screen turned ON. To
reset the error, press
12 Troubleshooting
Description
Boiler standby abnormality
OU: Transmission malfunction
between main CPU- INV CPU
Connection with LAN adapter lost
Connection with room thermostat
lost
No connection with room
thermostat
Unknown USB device
File malfunction
Boiler communication error
P1P2 communication error
Boiler communication error
Indoor unit, outdoor unit matching
problem
Tank type problem
Extension/hydro mismatch
problem
Communication problem between
control box and option box
Boiler, indoor unit matching
problem
Reversed piping or bad
communication wiring detection
and confirm by pressing
.
Installer reference guide
81