9 ] Firmware Version Up Procedure - Sharp DM-FX1 Service Manual

Digital copier fax expansion kit
Table of Contents

Advertisement

DM-FX1
[9] FIRMWARE VERSION UP PRO-
CEDURE
1. Cases where firmware version up is re-
quired
The firmware of the flash memory on the FAX control PWB must be
revised in the following cases:
1) When a bug or an error is found.
2) When data in the flash memory is destroyed or deleted.
2. Maintenance Fax Program
The maintenance FAX Program is a utility software which is used to
write into the download card used in version up of the DM-2000 series
FAX program. The operating procedure is as follows:
A. Use environment
Personal computer: Windows95 (Japanese or English) machine with
PCMCIA card slot
Download software: Maintenance Fax Program
Download card: UKOG-0008QSZZ (BN-S04MF4C)
Card adapter: UKOG-0009QSZZ (BN-SPCADP)
Necessary file: CardAPI (Made by Adtek System Science) must be in-
stalled. Program data
B. Installation of the program
(1) CardAPI installing procedure
1) Select "Setup.inf" in the CardAPI disk and right-click the mouse
to open the menu.
2) Select "Install" in the menu. The file is automatically copied.
3) Resume the system.
(2) Maintenance FAX Program installing procedure
1) Double-click "Setup.exe" in the setup disk 1 to start setup.
2) When setup is executed according to the setup withered direc-
tions, the icon is made in the start menu.
3) Double-click the icon to start the program.
C. Uninstallation of the program
(1) CardAPI uninstalling procedure
Uninstall is executed in "Add/Remove Programs" in the control
panel.
Follow the instructions of the uninstall withered to execute
uninstall.
(2) Maintenance FAX Program uninstalling procedure
Uninstall is executed in "Add/Remove Programs" in the control
panel.
Follow the instructions of the uninstall withered to execute
uninstall.
∗ Adlmf32.dll is a shared file. When CardUT97 is installed, do not
delete this file.
D. Program operation
(1) Starting the program
Double-click MFP.exe in the installed folder, or execute the pro-
gram from the start menu.
∗ This program cannot be multi-started. When it is tried to be multi-
started, an error message will be shown.
(2) Descriptions of the main menu
When MFP.exe is executed, the following main menu is displayed.
The main menu shows the following information.
<Slot status>
Slot ⋅⋅⋅ The selected card slot number is displayed. The card status is
also displayed with colors.
The card is inserted into the slot and is
Green
available for use.
The card is in standby or the battery is
Yellow
exhausted.
System color
The card is not inserted into the slot or the slot
(or gray)
cannot be used.
<Card device status>
Device ⋅⋅⋅ Availability of the card device type is displayed with colors.
The card device type is
Green
recognized as
Intel28F008_5V.
The card device type
cannot be recognized.
When the card size is
Yellow
not 4Mbyte and
Card(C)_SetDevice(V)_Inte
l28F008_5V is checked.
System
The card device type is
color
not set.
(or gray)
∗ The slot status is green and the card device status if green or yellow,
access to the card is allowed.
If access to the card is inhibited, the functions cannot be used ex-
cept for selection of the slot and ending the application.
<Card format type>
The operation type of the application is displayed.
If the inserted card has information on the card type, setup is automat-
ically made.
If the inserted card has no information on the card type, specify the
card type by checking either item of Card(C) _ SetCardType(T) on the
menu.
The operation type of the application is set
DownLoad Card
up in the DownLoad card.
Registration
The operation type of the application is set
Card
up in the Registration card.
Unknown Card
The operation type is not specified.
9 – 1
Access to the card is
allowed.
Access to the card is
allowed, but if the actual
card device differs, an
unexpected error may
occur.
Access to the card is
inhibited.

Advertisement

Table of Contents
loading

Table of Contents