Chapter 3 Basic Operations — Operating with the remote control

Using the status function

Display the status of the projector.
button
1)
Press the <STATUS> button.
f The [STATUS] screen is displayed.
Note
f The projector status can also be displayed using the menu operation. Refer to the [PROJECTOR SETUP] menu → [STATUS]
(x page 136) for details.

Setting ID number of the remote control

When you use the multiple projectors together, you can operate all the projectors simultaneously or each projector
individually using a single remote control, if a unique ID number is assigned to each projector.
After setting the ID number of the projector, set same ID number on the remote control.
The factory default ID number of the projector is set to [ALL]. When using a single projector, keep
pressing the <ID SET> button on the remote control for at least three seconds to set the ID number of
the remote control to [ALL]. In addition, when the ID number of the projector is unknown, setting the ID
number to [ALL] enables the remote control.
button
1)
Press the <ID SET> button on the remote control.
2)
Within five seconds, press the two‑digit ID number set on the projector using the number (<0> ‑ <9>)
buttons.
f When the ID number is set to [ALL], you can control the projector regardless of the ID number setting of the
projector.
Attention
f Since the ID number of the remote control can be set without the projector body, do not press the <ID SET> button on the remote control
carelessly. If the <ID SET> button is pressed and no number (<0> - <9>) buttons are pressed within five seconds, the ID number returns to
its original value before the <ID SET> button was pressed.
f The ID number set on the remote control will be stored unless it is set again. However, it will be erased if the remote control is left with dead
batteries. Set the same ID number again when the batteries are replaced.
Note
f When the ID number of the remote control is set to [0], you can control the projector regardless of the ID number setting of the projector
body, as same as when [ALL] is set.
f Set the ID number of the projector body from the [PROJECTOR SETUP] menu → [PROJECTOR ID].
72 - ENGLISH
STATUS
PROJECTOR TYPE
RZ770(123456789012)
PROJECTOR RUNTIME
100000h
LIGHT RUNTIME
100000h / 100000h
MAIN/SUB VERSION
1.00 / 1.00
INTAKE AIR TEMP.
31°C/87°F
OPTICS MODULE TEMP.
27°C/80°F
EXHAUST AIR TEMP.
31°C/87°F
31°C/87°F
LIGHT1 TEMP.
LIGHT2 TEMP.
31°C/87°F
COOLING CONDITION
AUTO - FLOOR
ATMOSPHERIC PRESSURE
1013hPa
SELF TEST
NO ERRORS