Page 4
READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary. MH00630BS, MH00636BS - 320 Watts, 2.6 Amps MH00830BS, MH00836BS - 320 Watts, 2.6 Amps Power consumption shown above is the default power specs. Hoods with CFM Selector Technology enabled will consume...
Page 6
1 - Hardware package 1 - 6” round backdraft damper (pre-installed) 1 - 5W LED Light Strip 2 - Baffle Filters HARDWARE PACKAGE CONTENTS MH00630BS, MH00636BS (4) #6 x 1-1/2” (2) #6 x 1” (2) 4 x 8mm (3) Wire Nuts MH00830BS, MH00836BS (3) #6 x 1-1/2”...
Page 7
Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
Page 8
DUCTING A minimum of 6” round duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. x . C Use calculation worksheet to compute total duct work (Page 5).
Page 9
and installer. WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Page 10
4 " 4 " Standard Duct Cover Min. ducted 27 ” Min. recirc. 32” Max. ducted 42 ” RHEX001S Extension Min. ducted 46 ” Min. recirc. ” Max. ducted 80” 12" 8 " 4 " 16 " 8 " 16 " 16 "...
Page 11
11” ” STANDARD min. ducted - 26” min. recirc. - 31” max. - 49” RHEX008S EXTENSION min. ducted - 41” min. recirc. - 45-1/2” max. - 78-1/2” ” 1/16 , 35 ” 15/16” 7/16 ” 3/16...
Page 12
CAUTION: At least two installers are required due to the weight and size of the hood. Duct Cover Bracket 1. Measure from range top to hood bottom and mark line A. (24” minimum from range top) . 3-1/2" 2" 2. Plum and mark center line. 3.
Page 13
CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to desired hood bottom location and Duct Cover Bracket mark line A. (24” minimum from range top) . ” 2.
Page 14
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re- circulated back within the home.
Page 15
Power / Delay Off - Power / Delay o button will turn power on and o for the entire hood (fan and lights). - The hood will remember the last speed and light level it was last turned o at. - Delay O Feature: With the fan on, press and hold the power button for three seconds.
Page 16
SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth.
Page 17
CFM SELECT Some local codes limit the maximum amount of CFM a range hood can move. CFM Select allows you to control the maximum blower CFM of the range hood without the need for expensive make up air kits. CFM Select enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels;...
Page 19
TROUBLESHOOTING PROCEDURES Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
Page 20
DESCRIPTION PART# Optional Accessories RH006 Recirculating Kit RHRK006BS RH008 Recirculating Kit RHRK008BS Replacement Charcoal Filters (each) Z0F-C005 RH006 Extension Duct Cover RHEX001S RH008 Extension Duct Cover RHEX008S Replacement Parts Baffle Filter 50210034 Order replacement parts from us by calling 1.888.750.1698...
Page 21
STAPLE YOUR RECEIPT HERE Proof of the original purchase Limited Warranty date is needed to obtain service under warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-750-1698 Venting Services (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of range hoods (the “Products”) that such Products will be free from defects in materials or workmanship as follows: One Year Limited Warranty for Parts: For one year from the date of your original purchase of the Products, we will provide,...
Need help?