Error Code
Description
E50/E55
inverter board
speed signal lost
or blocked.
frequency board
E50/E56
motor
overtemperature.
frequency board
E50/E57
radiator
overtemperature.
E50/E58
frequency board
motor overload
or motor open
phase.
E50/E5B
inverter board
reset fault.
E50/E5C
inverter board
overvoltage.
E50/E5D
inverter board
undervoltage
E50/E5E
inverter board
ultra high voltage.
inverter board
E50/E5F
read write flash
fault.
E50/E5A Inverter
Communication
Failed.
NOTE: It's important to note error codes should only be used to help identify those components which
require testing. Never replace a part based solely on an error code. The control can generate a false error
if the right conditions exist . Use the code only as a reference and always check the component before
replacing.
Problem
inverter
change the inverter.
board speed
signal lost
motor
• change the inverter.
overtemperature
frequency board
change the inverter
radiator
overtemperature
frequency
1. check motor wire
board motor
2. change inverter
overload or
3. check whether the system is blocked.
motor open
phase.
change the inverter.
inverter board
reset fault.
inverter board
check power system
overvoltage.
inverter board
check power system
undervoltage.
inverter board
check power system
ultra high
voltage.
inverter board
change the inverter.
read write flash
fault.
Check the inverter communication wire
Can not check
Chek the inverter
the
Check the main contorl
communication
– 61–
Possible Cause/Action