Command Control; Control Command Via Lan - Panasonic TH-49AF1U Operating Instructions Manual

Hide thumbs Also See for TH-49AF1U:
Table of Contents

Advertisement

Touching the LAN Terminal with a statically charged
hand (body) may cause damage to the device due to
its discharge.
Do not touch the LAN Terminal or the metal part of
the LAN cable.
For instructions on connection, consult your network
administrator.

Command control

Network function of the unit can control the unit in the
same way as serial control from a network.
Supported commands
Commands used in the serial control are supported.
(see page 27)

Control Command via LAN

The communication differs whether [LAN Control] -
[Control Protocol] in OpenPort PLATFORM is set to
[Protocol1] or [Protocol2].
1. When [Control Protocol] is set to
[Protocol1].
Communicates using the display-specific protocol.
When the command control administrator
privileges password has been set (Protect
mode)
Connection method
1
Obtain the display's IP address and the port number
(Default is 1024), and request connection to the
display.
The IP address and the port number can be obtained
from the following menus.
IP address:
[STATUS] in OpenPort PLATFORM (see page 52)
or [WIRELESS & NETWORKS] (see page 55)
Port number:
[LAN Control] in OpenPort PLATFORM (see page
54)
2
The display responds.
Response data
Data part Space
[PDPCONTROL]
[ ]
(ASCII
character
0x20
string)
10 bytes
1 byte
Mode: 1 = Protect mode
100
English
Random
Mode
Space
number
part
[zzzzzzzz]
[1]
[ ]
(ASCII
0x31
0x20
code hex
number)
1 byte
1 byte
8 bytes
3
Hash the following data with the MD5 algorithm, and
generate a 32-byte hash value.
[zzzzzzzzyyyyy]
zzzzzzzz :
8-byte random number obtained in step 2
yyyyy :
Command control administrator privileges user
Default user name and password are as follows:
User name: admin1
Password: panasonic
Command transmission method
Transmit in the following command format
Transmitted data
Header
Hash value
(see
"Connection
method")
32 bytes
Received data
Control
symbol
(STX)
0x02
1 byte
Error response
Error message
"ERR1"
Last
"ERR2"
terminal
symbol
"ERR3"
(CR)
0x0d
"ERR4"
1 byte
"ERR5"
"PDPCONTROL
ERRA"
4 bytes or 15 bytes
Control
Control
Data part
symbol
symbol
Control
command
(STX)
(ETX)
(ASCII
0x02
0x03
character
string)
1 byte
Undefined
1 byte
Control
Data part
symbol
Control
command
(ETX)
(ASCII
0x03
character
string)
Undefined
1 byte
: Undefined control
command
: Out of parameter
range
: Busy status or
reception invalid
period
: Timeout or reception
invalid period
: Wrong data length
: Mismatching of
password
Last
terminal
symbol
(CR)
0x0d
1 byte
Last terminal
symbol
(CR)
0x0d
1 byte
Last
terminal
symbol
(CR)
0x0d
1 byte

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-55af1uTh-42af1uTh-55af1wTh-49af1wTh-42af1wTh-49af1

Table of Contents