Command control

Network function of the unit can control the unit in the
same way as serial control from a network.
Supported commands
Commands used in the serial control are supported.
(see page 27)

Control Command via LAN

The communication differs whether [Options] - [LAN
control protocol] is set to [Protocol 1] or [Protocol 2].
The communication also differs depending on whether
the WEB control administrator privileges password is set
(Protect mode) or is not set (Non-protect mode).
Use the non-protect mode only when using a dedicated
system which is not used by someone other than the
network administrator.
Use the protect mode when operating within the intranet
that may be used by a third party.
Note
Immediately after the command (received data) is
sent, the network connection is automatically cut from
the unit.
The above specification is adopted from the security
stand point (to prevent manipulation of this product by
a malicious third party). When sending commands in
a row, request network connection each time before
transmission.
1. When [LAN control protocol] is set
to [Protocol 1].
Communicates using the display-specific protocol.
When the WEB control administrator
privileges password has been set (Protect
mode)
Connection method
1
Obtain the display's IP address and the port number
(Default is 1024), and request connection to the
display.
The IP address and the port number can be obtained
from the following menus.
IP address:
[Setup] → [Network settings] → [LAN setup] or
[Network status]
Port number:
[Setup] → [Network settings] → [LAN setup]
For more detail of the settings, see page 68, 69.
2
The display responds.
Response data
Data part Space
Mode
[PDPCONTROL]
[ ]
[1]
(ASCII
character
0x20
0x31
string)
10 bytes
1 byte
1 byte
Mode: 1 = Protect mode
3
Hash the following data with the MD5 algorithm, and
generate a 32-byte hash value.
[zzzzzzzzyyyyy]
zzzzzzzz :
8-byte random number obtained in step 2
yyyyy :
Password of the WEB control administrator privileges
user
Default user name and password are as follows:
User name: dispadmin
Password: @Panasonic
Random
Last
Space
number
terminal
part
symbol
[zzzzzzzz]
[ ]
(CR)
(ASCII
0x20
code hex
0x0d
number)
1 byte
8 bytes
1 byte
English
83