Omron E3NX-FA Operation Manual page 98

Ethercat digital sensor communication unit
Table of Contents

Advertisement

8 Troubleshooting and Maintenance
Event name
Non-volatile Memory Hardware Error
Meaning
An error occurred in non-volatile memory.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
Non-volatile memory failure
Attached
None
information
Precautions/
This error is not recorded in the error log of the slave.
Remarks
8 - 14
Source details
Observation
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
---
Correction
Replace the EtherCAT Communica-
tions Unit or the EtherCAT slave.
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
Event code
04A10000 hex
Slave
Detection
timing
---
Log category
Non-volatile memory cannot be written.
EtherCAT LINK/ACT
---
Name
---
Prevention
None
When establish-
ing communica-
tions after turning
ON power to the
slave