Omron E3NX-FA Operation Manual page 154

Ethercat digital sensor communication unit
Table of Contents

Advertisement

A Appendices
4F00 to 4F7F hex
Object for Selection of Multiple Units
Subindex 0: Number of Entries
*1
Range:
Size: 1 byte (U8)
Subindex 1: Multi (*2)
Range: 0000000000000000 to
FFFFFFFFFFFFFFFF hex
Size: 8 bytes (U64)
Subindex 2: Multi (*2)
Range: 0000000000000000 to
FFFFFFFFFFFFFFFF hex
Size: 8 bytes (U64)
*1 The setting range and default settings are the same as the values for the objects that are used from unit
numbers 1 to 30.
*2 This is the same as the name of the objects that are used from unit numbers 1 to 30.
• Bit 0 to 31 set values:
There is a different set value for each object. Set the values to write.
• Bit 32 to 61set values:
These bits are used to specify the unit numbers of the Sensors to which to write object data. Turn ON
the bits that correspond to the target unit numbers.
To write to all Sensors from unit numbers 1 to 30, you can turn OFF all bits 32 to 61.
• Bit 62 and 63 set values:
0 (not used)
Set data:
63, 62, 61... 32, 31 ... 0 [bit]
Not
used: 0
Example:
Case 1
This example sets the Threshold 1 Input 1 object for unit numbers 1, 10, and 30 to 1000 decimal.
Case 2
This example sets the display mode for all unit numbers from 1 to 30 to blinking.
A - 50
Unit: ---
Access: RO
Unit: ---
Access: RW
Unit: ---
Access: RW
Data
Unit
to write
number
selections
Write the following data for an index of 0x4F04 and subindex of 0x01:
0x20000201000003E8.
Write the following data for an index of 0x4F17 and a subIndex of 0x01:
0x0000000000000001 or 0x3FFFFFFF00000001.
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
*1
Default:
PDO map: Not possible
Default: 0000000000000000 hex
PDO map: Not possible
Default: 0000000000000000 hex
PDO map: Not possible
Attribute: ---
Attribute: A
Attribute: A