A Appendices
4020 + (N-1) × 80
No_01 ... 30 Hysteresis Width Setting
hex
Subindex 0: Number of Entries
Range: 02 hex
Size: 1 byte (U8)
Subindex 1: No_01 ... 30 Hysteresis Width Setting IN1
Range: 0000 to FFFF hex
Size: 2 bytes (U16)
Subindex 2*: No_01 ... 30 Hysteresis Width Setting IN2
Range: 0000 to FFFF hex
Size: 2 bytes (U16)
• This object sets the hysteresis width setting of the Sensor with the unit number that is specified by the
index.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
Data
0000 hex
0001 hex
0002 to FFFF hex
4021 + (N-1) × 80
No_01 ... 30 Hysteresis Width 1
hex
Subindex 0: Number of Entries
Range: 02 hex
Size: 1 byte (U8)
Subindex 1: No_01 ... 30 IN1
Range: 00000000 to 05F5 E0FF hex
Size: 4 bytes (U32)
Subindex 2: No_01 ... 30 IN2
Range: 00000000 to 05F5 E0FF hex
Size: 4 bytes (U32)
• This object sets the Hysteresis Width 1 setting of the Sensor with the unit number that is specified by
the index.
• FA□0, LA0, SA0, or FAH0 is assigned to the hysteresis width of IN 2 of normal detection mode by
Subindex 2.
• MA0, EA□0, AA□0, VA□0, or VD□0 is assigned to the hysteresis width of normal detection mode and
the high/low hysteresis width of area detection mode.
• The setting range for FA□0, LA0, SA0, FAH0, MA0, EA0, or VD□0 is 0000 0000 to 0000 270F hex.
4022 + (N-1) × 80
No_01 ... 30 Hysteresis Width 2
hex
Subindex 0: Number of Entries
Range: 01 hex
Size: 1 byte (U8)
Subindex 1: No_01 ... 30 IN1
Range: 00000000 to 05F5 E0FF hex
Size: 4 bytes (U32)
*2
Subindex 2: No_01 ... 30 IN2
Range: 00000000 to 05F5 E0FF hex
Size: 4 bytes (U32)
• This object sets the Hysteresis Width 2 high setting of the Sensor with the unit number that is
specified by the index.
• FA□0, LA0, SA0, or FAH0 is assigned to IN1 of normal detection mode and the high/low hysteresis
width of area detection mode by Subindex 1.
• MA0, EA□0, AA□0, VA□0, or VD□0 do not use this object.
• The setting range for the FA□0, LA0, SA0, FAH0, MA0, EA0, or VD□0 is 00000000 hex to 0000270F hex.
A - 36
Unit: ---
Default: 02 hex
Access: RO
Unit: ---
Default: --- hex
Access: RW
Unit: ---
Default: --- hex
Access: RW
Setting
Standard
User setting
Not used.
Unit: ---
Default: 02 hex
Access: RO
Unit: ---
Default: - hex
Access: RW
Unit: ---
Default: - hex
Access: RW
Unit: ---
Default: 01 hex
Access: RO
Unit: ---
Default: - hex
Access: RW
Unit: ---
Default: - hex
Access: RW
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
Attribute: ---
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: ---
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: ---
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: A
PDO map: Not possible