Photometric Chart; Installation - ADJ 1226100300 User Instructions

Table of Contents

Advertisement

Flat Par QA12XS
Flat Par QA12XS
The Flat Par QA12XS is fully operational in three different mounting
positions, hanging upside-down from a ceiling, hanging sideways on
trussing, or set on a flat level surface. The unit should be mounted
using a mounting clamp (not provided), affixing it to the mounting
bracket that is provided with the unit. Always ensure that the unit is
firmly fixed to avoid vibration and slipping while operating. Always
ensure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times the unit's weight. Also,
always use a safety cable that can hold 12 times the weight of the
unit when installing the fixture.
The equipment must be installed by a professional, and it must be
installed in a place where it is out of the reach of people's grasp.
ADJ Products, LLC - www.adj.com - Flat Par QA12XS User Manual Page 21

Photometric Chart

REMOTE
INPUT
OUTPUT

Installation

SOUND
CONTROL
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
1
DMX512 OUT
3
3-PIN XLR
2
Flat Par QA12XS
Notice:
Be sure to follow figures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable's shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR's outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 OUT
REMOTE
INPUT
SOUND
CONTROL
INPUT
XLR Male Socket
1 Ground
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
COMMON
DMX +
1
DMX512 IN
3
3-PIN XLR
DMX -
2
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
ADJ Products, LLC - www.adj.com - Flat Par QA12XS User Manual Page 6
POWER
DMX512
DMX+,DMX-,COMMON
COMMON
DMX +
1
3
3
3-PIN XLR
DMX -
2
OUTPUT
SOUND
XLR Female Socket
2 Cold
2 Cold
1 Ground
3 Hot
3 Hot
POWER
When longer runs of cable are
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3
to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin DMX-
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
Pin 1
Pin 2
Pin 3
Not Used
Not Used
Set Up
POWER
Termination redu
avoids signal tra
1
1
DMX512 IN
and interference.
3
3-PIN XLR
2
2
to connect a DMX
120 Ohm 1/4 W)
Figure 2
and PIN 3 (DMX
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
XLR Pin Configuration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
POWER
Figure 4
5-Pin XLR Male (In)
Pin 1
Pin 2
Pin 3