Advertisement

Quick Links

ENCORE
BURST 100IP
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ADJ ENCORE BURST 100IP

  • Page 1 ENCORE BURST 100IP User Manual...
  • Page 2 ©2022 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying prod- uct names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction Limited Warranty (USA Only) Warranty Registration | Features Safety Precautions IP Notice Installation Overview DMX Set Up DMX Addressing DMX Traits Dimmer Speed Chart System Menu Operating Instructions Multiple Unit Power Linking | Dimmer Mode Chart Dimensional Drawings | Trouble Shooting | Cleaning FCC Statement Specifications...
  • Page 4: Introduction

    INTRODUCTION Unpacking: Thank you for purchasing the Encore Burst 100IP by ADJ Products, LLC. Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to have been damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to oper- ate the unit have arrived intact.
  • Page 5: Limited Warranty (Usa Only)

    The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
  • Page 6: Warranty Registration | Features

    WARRANTY REGISTRATION The Encore Burst 100IP carries a 2 year (730 days) limited warranty. Please fill out the enclosed war- ranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package.
  • Page 7: Safety Precautions

    SAFETY PRECAUTIONS For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit! • To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture •...
  • Page 8: Ip Notice

    IP NOTICE IP65 RATED An IP rated lighting fixture is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP” followed by two numbers (i.e.
  • Page 9: Installation

    INSTALLATION Always ensure that the unit is firmly fixed in order to avoid vibration and slipping during operation. The structure that the unit is attached to must be secure and capable of supporting at least 10 times the unit’s weight. ALWAYS use safety cables that can support at least 12 times the weight of the unit when installing the fixture.
  • Page 10: Overview

    OVERVIEW CONTROL PANEL & LCD SCREEN (MODE/UP/DOWN/ENTER BUTTONS) 5-PIN DMX IN 5-PIN DMX OUT POWER IN POWER OUT SAFETY CABLE RIGGING POINT...
  • Page 11: Dmx Set Up

    2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
  • Page 12: Dmx Addressing

    DMX ADDRESSING DMX ADDRESSING When using a DMX controller, all fixtures should be given a DMX starting address in order to ensure that the correct fixture responds to the correct control signal. This digital starting address is the chan- nel number from which the fixture starts to “listen” to the digital control signal sent out from the DMX controller.
  • Page 13: Dmx Traits

    DMX TRAITS CHANNEL DMX VALUES FUNCTION 1 CH 2 CH 3 CH 4 CH Master Dimmer, 0% to 100% 000 - 255 Dimmer Fine, 0% to 100% 000 - 255 Shutter and Strobing 000 - 031 Shutter Closed (LED Off) 032 - 063 Shutter Open (LED On) 064 - 095...
  • Page 14: Dimmer Speed Chart

    DIMMER SPEED CHART DELAY AND MENU DMX VALUES DISPLAY TIME 0.1s 0.2s 0.3s 0.4s 0.5s 0.6s 0.7s 0.8s 0.9s 1.0s 1.5s 2.0s 3.0s 4.0s 5.0s 6.0s 7.0s 8.0s 9.0s 10.0s...
  • Page 15: System Menu

    SYSTEM MENU DMX Address 001 - 512 Set DMX address Select DMX channel DMX CH Mode mode Hold Last Set fixture action when No DMX State Blackout DMX signal is lost Manual Standard Stage Select dimming curve Dim Modes Architectural modes and set dim speed Theatre...
  • Page 16 SYSTEM MENU Power On Time Total running time, non xxxxxx Hours resettable P-On Time-R Running time, reset- Fixture Life Time xxxxxx Hours table P-On Time Reset Reset running time Passcode = 050 LED On Time Total LED On running xxxxxx Hours time, non resettable LED On Time-R LED On running time,...
  • Page 17: Operating Instructions

    OPERATING INSTRUCTIONS DMX Address - DMX Address Setting. 1. Press either the MENU, UP, or DOWN buttons until “DMX Address” is displayed, then press ENTER. 2. The current DMX address will be displayed. Press the UP or DOWN buttons to find your desired DMX address and press ENTER to confirm your setting.
  • Page 18 OPERATING INSTRUCTIONS Tungsten - This effect simulates the use of a tungsten filament light. 1. Press either the MENU, UP, or DOWN buttons until “Tungsten” is displayed, then press ENTER. 2. Use the UP or DOWN buttons to toggle between “ON” and “OFF”. “ON” will activate this effect, and “OFF”...
  • Page 19 OPERATING INSTRUCTIONS P-On Time-R - With this function you are able to check the number of hours that the fixture has been powered on since the last reset. Please note: This time value can be reset, so it may not be the same as the total power ON running time displayed under “POWER ON TIME”.
  • Page 20 OPERATING INSTRUCTIONS Max Resettable - With this function you are able to check the highest temperature the fixture has reached since its last reset. This temperature can be reset, and therefore it may not be the same as the temperature displayed under “CURRENT” or “MAX NOT RESETTABLE”. 1.
  • Page 21: Multiple Unit Power Linking | Dimmer Mode Chart

    MULTIPLE UNIT POWER LINKING With this feature you can connect the fixtures to one another using the power cable input and output sockets. USE CAUTION WHEN POWER LINKING FIXTURES OF OTHER MAKE AND MODEL TYPES, AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
  • Page 22: Dimensional Drawings | Trouble Shooting | Cleaning

    DIMENSIONAL DRAWINGS 9.21” / 234mm TROUBLE SHOOTING Listed below is a common problem the user may encounter, with possible solutions. Unit not responding to DMX: Check that the DMX cables are connected and wired correctly (pin 3 is “hot”; on some other DMX de- vices, pin 2 may be “hot”).
  • Page 23: Fcc Statement

    FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two condi- tions: (1) this device may not cause harmful interference, and (2) this device must accept any interfer- ence received, including interference that may cause undesired operation. FCC RADIO FREQUENCY INTERFERENCE WARNINGS &...
  • Page 24: Specifications

    SPECIFICATIONS Model: Encore Burst 100IP Voltage: 100V ~ 240V / 50~60 Hz LEDs: 1 x 125W Warm White COB CREE LED Color Temperature: 2700K 1200K (Tungsten Mode) IP Rating: IP65 Working Position: Any Safe Working Position Power Draw: 115 W Weight: 9.25 Lbs / 4.2 Kgs...

Table of Contents